19
MAINTENANCE NOTE FOR DIA100
Change of Cotton Filament (76-1411030):
Please note that the cotton filament cannot be washed with the water. Water drops would be sucked
into the Pump and may cause the pump damaged within 1 to 2 months. If you wash with the water,
Cotton filament
will turn solid and will stop the DIA100 working well. Please change
at least
once
3 to 5 days if you use
8 hours
per day.
Change of Charcoal Filter (78-151500):
Charcoal filter will turn solid if you wash with the water. If you use 8 hours per day that the Charcoal
filter has to be changed within 3 weeks. On the other hand, if you wash the Charcoal filter and do not
dry properly, water drops will be sucked into the Pump and may cause the pump damaged easily.
Change of Glass Solder Collector (75-160110):
Glass solder collector will be broken easily if the client knocked the DIA100 against the desktop.
The glass collector also needs to be changed every 3 to 5 months usage.
Maintenance for Desoldering Heater and Tip:
To prevent the desoldering tip being stuck by solder, the desoldering tip has to be cleaned by a Probe
after every time usage. In such ways, desoldering tip’s life can be lasting longer. Desolder Heater
would be probably broken when you remove the desoldering tip with a pliers careless in hot
condition. Slightly remove the tip with pliers or may use the anti-rusty cleaner when the tip clogged
with the heater and do not forced open. Please read the “
Procedure for
Cleaning Clogged Tips
”
carefully on page18 on the manual.
PROCEDURE FOR REPLACING HOT AIR GUN HEATING ELEMENT
1.Unscrew the 3 screws on handle then take out the handle cover.
(See Fig.1 below)
2.
Disconnect the grounding wire jack and pull the heating element out from the stainless steel tube.
(See Fig.2 below )
1.
Pull the default heater off and replace a new one then re-assembly the heater according the
Important:
Do not damage or loss the quartz glass and /or insulation
mica inside of the stainless steel tube.
Caution
:
The main swich must be “off” and allow the iron to cool
before attemptling the following procedure