Revision 3.1
WebRelay
TM
Users Manual
equals local relay
”. Note that the relay contacts of each WebRelay
TM
will be set to the same state as the
contacts of the WebRelay
TM
that is configured to control it and not necessarily to the state of the switch. In
other words, if the switch is 'ON' but a user changes the state of WebRelay
TM
3 to 'OFF' by changing the
relay in the web page, WebRelay
TM
4 will be changed to the 'OFF' state also. Note also that in this example,
WebRelays 2, 3, and 4 are each controlling load devices and WebRelay
TM
1 is not, but a load could be
connected to WebRelay
TM
1 as well.
1.4.5 WebRelay
TM
Used for Reboot (Wired in series with Power)
The illustration below shows one example of how WebRelay
TM
can be used to reboot a server. WebRelay
TM
is wired in series with the servers power source which allows it to turn the server on and off.
Xytronix Research & Design, Inc.
page 10
Power Supply
For Device Server
WebRelay
+5
V
Power Supply
For WebRelay
Device Server
(Camera Server, Serial Server, etc.)
(This is the device to be remotely re-booted)
Cut one wire in the power
supply cable and connect to
WebRelay contacts.