14. Input Description:
This is the text that will be displayed next to the input status when the ‘Display Input Status’ is enabled. It
can be up to 20 characters in length.
15. Input ON Color:
When ‘Display Input Status’ is set to
Yes
, this field specifies the color that will be displayed when the input
is
on
(voltage applied to input).
16. Input ON Text:
When ‘Display Input Status’ is set to
Yes
, this field specifies the text that will be displayed when the input is
on
(voltage applied to input).
17. Input OFF Color:
When ‘Display Input Status’ is set to
Yes
, this field specifies the color that will be displayed when the input
is
off
(voltage is not applied to input).
18. Input OFF Text:
When ‘Display Input Status’ is set to
Yes
, this field specifies the text that will be displayed the input is
off
(voltage is not applied to input).
19. Auto Refresh Page:
Web pages traditionally display static information. The WebRelay
TM
control page, however, displays
information that is dynamic. Each time the control page is loaded to the browser, it displays a snapshot of
the current status of the unit. If the state of the unit changes, the information on the control page will be
outdated unless the page is re-loaded. Whenever a user changes the state of the relay via the web browser,
the web page will automatically reload the control page to display current information. If, however, the
relay state changes due to a change in the control voltage input or due to a command sent from another
machine, the relay state will not be updated and the control page information will be obsolete. In addition,
when the optically-isolated input changes, the control page will be obsolete until the page is refreshed.
WebRelay
TM
can not force the web page to be updated when the input changes. The ‘Auto Refresh Page’
option will cause the control page to continually update its contents by setting a timer in the web page that
causes it to be reloaded at a specified time interval.
20. Duration:
If the ‘Auto Refresh Page’ option is set to
Yes
, this field specifies the time interval in seconds that the page
will be refreshed. It can be set from 1 to 32 seconds.
2.4.6 Control Page Setup (When Relay Mode is set to Automatic Reboot)
Once WebRelay
TM
is set up, it can be controlled and monitored using a web browser by accessing its control
page. Titles, colors, and basic content of the control page can be customized by setting the appropriate
options in the ‘Control Page Setup’ page. Note that this setup page only affects the control web page and
does not affect the function of WebRelay
TM
in any way. This section describes the ‘Control Page Setup’
page when the relay mode is set to
Auto Reboot.
1. Main Header Text:
This text will be displayed in the main header area of the control page. This field can be up to 25 characters
in length.
2. Relay Description:
This text is used to describe the function of the relay on the control page. This text will not appear if the
‘Display Relay Status’ is set to
No
, and ‘ON/OFF’ buttons are not displayed which allow relay control. This
field can be up to 20 characters in length.