— 42 —
Syntax
Examples
Description
YD:CHARGE_EFF [50..100]
YD:CHARGE_EFF 90
Specifies Charge Efficiency Factor
(in percent) in PGN 127513 «Battery
Configuration Status the ratio
between the amount of energy
removed from a battery during
discharge and the amount of energy
used to restore the original capacity
during charging (50..100%, integer
value). The value 100 disables
the charge efficiency compensation.
Charge Efficiency of Li-ion batteries
higher than Lead Acid batteries:
recommended value is 99%.
Factory setting: 95.
YD:CALCS [ON|OFF]
YD:CALCS ON
Enables or disables calculations
of the battery status information
(SoC, consumed ampere-hours, time
remaining, SoH). When set to OFF,
only battery instance and DC Type
data is included into NMEA 2000
PGN 127506 «DC Detailed Status».
Factory setting: OFF
IMPORTANT: When applied, this
command automatically resets all
calculation results for SoC, consumed
ampere-hours and time remaining,
SoH (see IX.1, Note 1 to Table 1).
Table 1 continued
Summary of Contents for NMEA 2000 YDBM-01