![background image](http://html1.mh-extra.com/html/yacht-devices/ydeg-04/ydeg-04_user-manual_3081541038.webp)
— 38 —
34. TRANS_ALERT_x=[y,w,z|OFF]
x — digit from 0 to 9, internal index of the Device
y — 5-bit mask, hexadecimal number 00…1F
w — decimal number of SPN, see the manual of your specific engine
z — decimal number FMI, from 0 to 31, see the manual of your engine
When a diagnostic message (PGN 65226) with specified SPN and FMI codes is received from the engine’s
transmission, set the bits of the transmission status in NMEA 2000 according to the mask. For example:
TRANS_ALERT_0=08,124,18
Set the fourth bit (hexadecimal 08) in the transmission status (see Appendix B, Table 2), indicating
«Low Oil Level», when a diagnostic message received with the SPN and FMI equal to 124 and 18,
respectively.
35. SMARTCRAFT=ON|OFF|HANDSHAKE
Factory setting: OFF
Activates SmartCraft protocol support used in Mercury and MerCruiser engines (see IV.4 for details).
Use the HANDSHAKE value if you have a limited set of data (the RPM only) in NMEA 2000 (required for
some old engines with analog gauges). Switch between on and off resets tilt/trim calibration (see V.37-39)
to default values for the selected system.
36. MEFI4B=ON|OFF
Factory setting: OFF
This settings turns on use of proprietary Volvo Penta messages with tilt/trim data available in MEFI 4B
only. Switching between on and off resets tilt/trim calibration (see V.37-39) to values for selected system.