1.3.2 Connection to a 2-coil gauge
If the gauge has two coils, the VREF terminal should be connected to the gauge’s power terminal (up to 16
Volts), the SENS terminal to the gauge’s «Signal» input (or to the fluid level sensor’s «Signal» wire after the
measurement activation button, see Figure 3), and the GND terminal to the gauge’s «Ground» terminal.
You should also configure the channel and set the CONNECTION setting to 2COIL for connection scheme
shown on the right part of Figure 3 (or if your gauge has no buttons) or to 2COIL_VCC for connection
scheme shown on the left part of Figure 3 (see Section VI.3.1).
(1) — YDTA-04, (2) — Gauge, (3) — Fuel Sensor, (4) — Optional Button, (5) and (6) — Parallel Sensors
(optional)
Figure 3. Connection in parallel with an existing 2-coil analog gauge