— 22 —
1.3 YD:DEV [0..255]
Switches NMEA 2000 devices instance to specified value. This setting is used in large NMEA 2000
networks and does not effect the Device’s behavior.
1.4 YD:SYS [0..15]
Switches the NMEA 2000 system instance of the Device to the specified value. This setting is used in large
NMEA 2000 networks and does not effect on Device’s behavior.
1.5 YD:PGN <pgn> [OFF | 0 | 100..60000]
Where: <pgn> is 126993, 127505 or 127496 (see Appendix B)
Set transmitting interval for specified PGN, the value is in milliseconds. OFF or 0 disable periodic PGN
transmission.
Example 1
. Set the periodic transmission interval for Fluid Level PGN to 1 second:
YD:PGN 127505 1000
Example 2
. Obtain the transmission interval for Heartbeat PGN:
YD:PGN 126993
2. Basic channel configuration
2.1 YD:TANK <A..D> [0..252]
The tank number, also known as the NMEA 2000 data instance. The first tank should have the number
0. Numbering is individual for each fluid type, e.g. the first diesel tank and the first fresh water tank both
have number 0.