VIII. Firmware Updates
Firmware updates can be done with free CAN Log Viewer software (version 1.35 or later) running on
Microsoft Windows, Mac OS X and Linux:
http://www.yachtd.com/products/can_view.html
The program must be connected to an NMEA 2000 network with a Yacht Devices USB Gateway YDNU-02,
or a Wi-Fi Gateway YDWG-02, or an Ethernet Gateway YDEN-02, or a Wi-Fi Router YDNR-02.
You can download the latest firmware version for the Tank Adapter YDTA-04 from our website (do not
confuse with YDTA-01 model firmware):
http://www.yachtd.com/downloads/
Open the downloaded .ZIP archive with the update and copy the YDTA04.BIN file to the disk. The
README.TXT file inside the archive can contain important information regarding the update.
1. Click the «NMEA 2000 Devices» item in the «View» menu.
2. Click the «Refresh» button (see Figure 1 on the next page) in the opened window and wait for the
Device to appear in the list.
3. Select the Device and click the «Firmware Update» button.
4. Locate and select the YDTA04.BIN update file on the disk.
5. Wait while the firmware is uploading.
If in doubt, see the video with the update procedure on our web site. During the firmware upload, the
Device’s status LED (N2K) flashes RED very fast. When the firmware is updated, the Device status LED
gives off the sequence of RED and GREEN half-second signals five times and the CAN Log Viewer also
informs you that the update is successfully done.
Summary of Contents for YDTA-04N
Page 1: ...User Manual Tank Adapter YDTA 04 also covers models YDTA 04N Firmware version 1 00 2021...
Page 6: ...6 I Product Specification Figure 1 Drawing of Tank Adapter YDTA 04N...
Page 28: ...28 Figure 1 Automatic management of ballast tanks with YDCC 04 and YDTA 04...
Page 33: ...33 Figure 1 Firmware update with CAN Log Viewer...
Page 40: ......