— 37 —
Note 1 : Sent every 60 seconds by default, interval can be changed in the Adapter’s settings (refer to
Section VI). The message reports failed equipment state if any of four external sensors is not
connected or malfunction. For unused channels, set the connection type to NC (see Section VI.3).
Note 2: Sent every 2.5 seconds for each channel by default, interval can be changed in the Adapter’s
settings (refer to Section VI).
Note 3 : Sent only if YD:JOIN command was used (see Section VI.4); the default transmission internal
is 1 second, can be changed in Adapter’s settings. If some other equipment sent this message,
the Adapter will immediately send its own message afterward with the corrected value of the
estimated fuel remaining.
Note 4: NMEA 2000 Device Instance, System Instance, Installation Description Field 1 and Installation
Description Field 2 can be changed with PGN 126208 (professional NMEA 2000 installer
software and hardware may be required)..