— 7 —
Device parameter
Value
Unit
Supply voltage (from NMEA 2000 network)
7..16
V
Current consumption (from NMEA 2000 network), avg./max
51 / 62
mA
Load Equivalency Number
2
LEN
Galvanic isolation between NMEA 2000 interface and sensor inputs
2500
V
RMS
Number of measurement channels
4
Maximum voltage on sensor and gauge reference voltage inputs
16
V
Voltage output sensor supported range
0..16
V
Fluid level sensors resistance range
0..400
Ohm
Analog gauge coils resistance range
0..10 000
Ohm
Sensor resistance/voltage measurement accuracy
±1
%
Device case dimensions (LxWxH)
85 x 46 x 29
mm
Weight
50
g
Operating temperature range
-20..55
°С
Yacht Devices Ltd declares that this product is compliant with the essential requirements of EMC
directive 2004/108/EC.
Dispose of this product in accordance with the WEEE Directive. Do not dispose of electronic refuse
with domestic or industrial waste.
Summary of Contents for YDTA-04N
Page 1: ...User Manual Tank Adapter YDTA 04 also covers models YDTA 04N Firmware version 1 00 2021...
Page 6: ...6 I Product Specification Figure 1 Drawing of Tank Adapter YDTA 04N...
Page 28: ...28 Figure 1 Automatic management of ballast tanks with YDCC 04 and YDTA 04...
Page 33: ...33 Figure 1 Firmware update with CAN Log Viewer...
Page 40: ......