( 3 ) S Mete r Sens itivity
a ) Apply the s i gnal g ene r ator output to the antenna conne cto r . P eak
Tl 0 2 fo r maximum S mete r reading .
b ) Set the output level o f the si gnal g enerato r to 2 0d B and adjust
VRlOl fo r full s cale indi cation on foe S mete r .
( 4 ) Noi s e Squelch Thre s hold
a) Re c e ive 0 dB s ignal from the s ignal g ene r ato r.
b ) Set the SQL contr ol on the front panel to TON E po s iti on and s li ght
ly advance clo ckwi s e di r e c tion to minimum SQL po sition . Set
VR1 0 2 to the point whe r e the s quelch s tarts to open.
PLL C i r cuit
a) S et the channel fr e quency to 14 6 . 00 MHz .
b ) C o nne c t the Y C 5 0 0 S frequency counte r t o T P 3 o f the P L L unit and
adju st T C 3 0 9 fo r 5 . 12 0 0 MHz, and make sur e the RF voltage o f the
emitte r of Q 3 1 2 i s appr oximately 1 . 6 Volts rm s .
c ) C onne ct R F p r ob e o f the V T VM to the ba s e o f Q 3 11 and p e ak T C 3 0 8
fo r maximum V TVM r e a ding . Slowly rotate T C 3 0 8 in the di r e c tion
of inc r e a s ing c apacitanc e until the V TVM r e ading b e c ome s 5 %
l ow e r than peak indic ation ( app r ox . 6 0 mV rms ) .
d ) C onne ct RF p r obe of the V T VM to the ba s e o f Q 3 0 5 . K e y the tran s
mitte r and p e ak T 3 0 2 fo r maximum V T VM r e ading ( approx . 17 0 mV
rm s ) .
e ) C onne ct the Y C - S O OS fr e qu ency c ount e r b e tw e en cathode o f D 3 0 2
in PLL unit and the g round . Set the FUNC TION switch to SIMP .
Adju s t T C 3 01 fo r 1 3 5 . 3 0 0 MHz c ounte r r e ading .
f) S et the FUN C TION switch to - 6 0 0 . K e y the tran s mitte r and adju s t
T C 3 02 fo r 1 3 4 . 7 0 0 MHz c ounte r r eading . Adju s t T C 3 0 3 fo r 1 3 5 . 9 0 0
MHz at + 6 0 0 .
g ) S e t the FUN C TION switch to SIMP . P r e s s 5 U P switch down . Ad
ju s t T C 3 04 fo r 1 3 5 . 3 0 5 MHz in r e c eive mod e . K ey the transmitte r
at - 60 0 and adju s t T C 3 0 5 fo r 134 . 7 0 5 MHz, at + 6 0 0 kHz adju s t
T C 3 0 6 fo r 1 3 5 . 9 0 5 MHz .
h) C onne ct V T VM ( D Cl O V r ang e ) betwe en the cathod e of D 3 2 4 and ground.
Adju s t T C 3 01 fo r 3 . 4 Volt V TVM r e ading .
i ) C onne ct RF probe o f V T VM between TX out te rminal and gr ound in
PLL unit . P eak T4 0 2 - T4 0 8 fo r maximum V T VM r e ading i n transmi t .