1
Introduction
This manual provides technical information necessary for servicing the FT-7100M FM Transceiver.
Servicing this equipment requires expertise in handling surface-mount chip components. Attempts by non-qualified
persons to service this equipment may result in permanent damage not covered by the warranty, and may be illegal in
some countries.
Two PCB layout diagrams are provided for each double-sided circuit board in the repeater. Each side of is referred to
by the type of the majority of components installed on that side (“leaded” or “chip-only”). In most cases one side has only
chip components, and the other has either a mixture of both chip and leaded components (trimmers, coils, electrolytic
capacitors, ICs, etc.), or leaded components only.
While we believe the technical information in this manual to be correct, VERTEX STANDARD assumes no liability
for damage that may occur as a result of typographical or other errors that may be present. Your cooperation in pointing
out any inconsistencies in the technical information would be appreciated.
©2002 VERTEX STANDARD CO., LTD. Printed in Japan.
Technical Supplement
FT-7100M
VHF/UHF Dual Band
FM Transceiver
Specifications ................................................. 2
Exploded View & Miscellaneous Parts ...... 3
Block Diagram ............................................... 4
Circuit Description .................................. 5
Alignment .................................................. 9
Contents
Board Unit (Schematics, Layouts & Parts)
MAIN Unit ............................................................. 17
PANEL Unit ........................................................... 53
VR Unit .................................................................. 65
POWER
BAND
V/M
HOME
MHz
TONE
REV
LOW
VERTEX STANDARD CO., LTD.
4-8-8 Nakameguro, Meguro-Ku, Tokyo 153-8644, Japan
VERTEX STANDARD
US Headquarters
10900 Walker Street, Cypress, CA 90630, U.S.A.
International Division
8350 N.W. 52nd Terrace, Suite 201, Miami, FL 33166, U.S.A.
YAESU EUROPE B.V.
P.O. Box 75525, 1118 ZN Schiphol, The Netherlands
YAESU UK LTD.
Unit 12, Sun Valley Business Park, Winnall Close
Winchester, Hampshire, SO23 0LB, U.K.
VERTEX STANDARD HK LTD.
Unit 5, 20/F., Seaview Centre, 139-141 Hoi Bun Road,
Kwun Tong, Kowloon, Hong Kong
EH003M90A
Summary of Contents for FT-7100M
Page 4: ...4 Block Diagram...
Page 18: ...MAIN Unit Lot 1 Note 18...
Page 22: ...MAIN Unit Lot 5 Note 22...
Page 52: ...52 MAIN Unit Note...
Page 54: ...54 PANEL Unit Lot 1 Note...
Page 56: ...56 PANEL Unit Lot 1 Note...
Page 58: ...58 PANEL Unit Lot 5 Note...
Page 60: ...60 PANEL Unit Lot 5 Note...
Page 64: ...62 PANEL Unit Note...
Page 65: ...65 Parts Layout Side A Side B Circuit Diagram VR Unit Lot 1...
Page 66: ...66 Parts Layout Side A Side B Circuit Diagram VR Unit Lot 5...