Introduction
This manual provides technical information necessary for servicing the FT-897 HF/VHF/UHF ALL MODE Trans-
ceiver.
Servicing this equipment requires expertise in handling surface-mount chip components. Attempts by non-qualified
persons to service this equipment may result in permanent damage not covered by the warranty, and may be illegal in
some countries.
Two PCB layout diagrams are provided for each double-sided circuit board in the Transceiver. Each side of is referred
to by the type of the majority of components installed on that side (“leaded” or “chip-only”). In most cases one side has
only chip components, and the other has either a mixture of both chip and leaded components (trimmers, coils, electrolyt-
ic capacitors, ICs, etc.), or leaded components only.
While we believe the technical information in this manual to be correct, VERTEX STANDARD assumes no liability
for damage that may occur as a result of typographical or other errors that may be present. Your cooperation in pointing
out any inconsistencies in the technical information would be appreciated.
©2002 VERTEX STANDARD CO., LTD. Printed in Japan.
Technical Supplement
FT-897
HF/VHF/UHF
ALL MODE Transceiver
Specifications................................................... 2
Exploded View & Miscellaneous Parts....... 4
Block Diagram ................................................. 5
Circuit Description ........................................ 7
Alignment....................................................... 10
Contents
Board Unit
(Schematics, Layouts & Parts)
MAIN Unit ............................................................... 21
PLL Unit ................................................................... 53
PA Unit ..................................................................... 59
PANEL Unit ............................................................. 73
MIC Unit .................................................................. 81
VR Unit ..................................................................... 82
BATT-CONN Unit .................................................. 83
REF Unit ................................................................... 84
VERTEX STANDARD CO., LTD.
4-8-8 Nakameguro, Meguro-Ku, Tokyo 153-8644, Japan
VERTEX STANDARD
US Headquarters
10900 Walker Street, Cypress, CA 90630, U.S.A.
International Division
8350 N.W. 52nd Terrace, Suite 201, Miami, FL 33166, U.S.A.
YAESU EUROPE B.V.
P.O. Box 75525, 1118 ZN Schiphol, The Netherlands
YAESU UK LTD.
Unit 12, Sun Valley Business Park, Winnall Close
Winchester, Hampshire, SO23 0LB, U.K.
VERTEX STANDARD HK LTD.
Unit 5, 20/F., Seaview Centre, 139-141 Hoi Bun Road,
Kwun Tong, Kowloon, Hong Kong
Summary of Contents for FT-897
Page 5: ...Block Diagram 5...
Page 6: ...Block Diagram 6 Note...
Page 21: ...21 MAIN Unit Circuit Diagram...
Page 22: ...22 MAIN Unit Note...
Page 52: ...52 MAIN Unit Note...
Page 59: ...59 PA Unit Circuit Diagram...
Page 60: ...60 PA Unit Note...
Page 73: ...73 PANEL Unit Circuit Diagram...
Page 74: ...74 PANEL Unit Note...
Page 75: ...75 PANEL Unit H Parts Layout Side A 1 2 3 F A C B E D BRPG1211C D4007 4010 4012 G...