5
I
NST
ALLA
TION
G-5400B/-5600B Az-E
L
Rotator
r
Connect the supplied DC cable to a source of 12 VDC.
The red lead connects to the Positive (+) DC terminal,
and the black lead connects to the Negative
(–) DC terminal. The
GS-232A
requires 110 mA. The
supplied cable has a 500-mA fast-blow fuse. Use only
the same type fuse for replacement.
r
Plug the coaxial power connector into the
DC 12V
jack
on the
GS-232A
rear panel.
r
Connect the supplied Control cable (“Dual 5-pin”
1
“DIN”) between the rotator’s controller and
GS-232A
.
Be careful to match the “
AZ
” and “
EL
” labels on the cable
with the same labels on the rear panel of the
GS-232A
(Figure 2).
G-400/G-500 or G-400/G-550 & pair of GX-500
r
Connect the supplied DC cable to a source of 12 VDC.
The red lead connects to the Positive (+) DC terminal,
and the black lead connects to the Negative
(–) DC terminal. The
GS-232A
requires 110 mA. The
supplied cable has a 500-mA fast-blow fuse. Use only
the same type fuse for replacement.
r
Plug the coaxial power connector into the
DC 12V
jack
on the
GS-232A
rear panel.
r
Connect the 5-pin to 5-pin cable (supplied with the
GX-
500
; requires two sets) between the
GX-500
(s) and
GS-
232A
(Figure 3).
P
OWER
& C
ONTROL
C
ONNECTIONS
GX-500
Figure 3
To DC 12V Power Source
To Serial port of the computer
To Elevation
Controller
To Elevation
Rotator
To Azimuth Controller
To Azimuth Rotator
GX-500
Figure 2
To DC 12V Power Source
To Serial port
of the computer
G-5400B/-5600B
or G-5500
A
Z
/E
L
Rotator