background image

Important!

The installation of a rotatable antenna on a tower system is a dangerous and potentially life-

threatening task, if due care is not taken.

A tower must never be installed in a position where it could fall across power distribution
cables in the event of a catastrophic tower failure during a windstorm or earthquake.

The control cable attached to this rotator could, in the event of a nearby or direct lightning
strike, carry lethal voltages down the cable and into your home. Yaesu strongly recommends
the installation of suitable lightning arrestors on all control cables and coaxial lead-in cables
from your antenna installation. See your dealer for details of available lightning-protection

devices.

If an electrical storm should be reported in your area, quickly unplug the control cable from
the rear of the rotator’s controller box, and disconnect the AC cable from the wall outlet.
Disconnect the coaxial cable(s) from the antenna(s) as well. 

 Do this only if the lightning is not

in your immediate area, as you could be killed instantly if lightning should strike while you are

holding a cable.

If you have any doubts about your ability to install this rotator safely, enlist the services of a
professional antenna installation company.

Sq. Ft

M

2

Sq. Ft

M

2

1

0.093

12

1.115

2

0.186

13

1.208

3

0.279

14

1.301

4

0.372

15

1.396

5

0.465

16

1.486

6

0.557

17

1.579

7

0.650

18

1.672

8

0.743

19

1.765

9

0.836

20

1.858

10

0.929

21

1.951

11

1.022

22

2.044

11

Summary of Contents for G-450A

Page 1: ...Cerritos CA 90703 U S A YAESU EUROPE B V Snipweg 3 1118DN Schiphol The Netherlands YAESU UK LTD Unit 12 Sun Valley Business Park Winnall Trading Estate Winchester Hampshire SO23 0LB U K YAESU GERMANY...

Page 2: ...center protrudes by f48 to f52 Rotation Range 450 360 Rotation Time 63 seconds at 50 Hz 51 seconds at 60 Hz Braking Type Mechanical stopper Mechanicalandelectricalstoppers Antenna K Coefficient 100 1...

Page 3: ...tion can be achieved using the optional GL 33 mast adjustment plate per the illustrations below Mast Diameter f32 to f38 Use two plates Mast Diameter f39 to f47 Use one plate Mast Diameter f48 to f50...

Page 4: ...Controller Front Rear Panel Controls and Switches Controller Front Panel Controller Rear Panel When replacing fuses be sure to use a fuse of the same type and current rating 2...

Page 5: ...Attachment Plate Dimensions The tower plate onto which the rotator unit is mounted must be drilled with four holes of 9 mm diameter equally spaced on a circle of 119 mm diameter The center to center...

Page 6: ...antenna of surface area of 0 3 m2 see Table 1 the above specifications for pole mounting will be met if A the antenna is mounted on a mast not longer than 0 8 m 0 3 0 8 0 24 0 25 and B if the mast we...

Page 7: ...arately for each an tenna using the relative heights of the two antennas to apportion the mast weight The antenna system K factor then is the sum of the two antenna K factors K1 K factor of 14 MHz 3 e...

Page 8: ...used Confirm that all solder joints are firm and cleanly made as this part of the cable will be difficult to access once the rotator is installed on top of the tower Do not slide the shell onto the c...

Page 9: ...Assembly of 6 pin Plastic Connector Assembly of 7 pin Metal Connector Wiring for the control cable identical numbers to be inte Pin No 7 for the metal connector is not used 7...

Page 10: ...be pointing exactly to 0 If the indicator needle is not pointing exactly to 0 go to the rear panel of the controller and set the Adjustment Potentiometer Selection Switch see Figure 2 to the right po...

Page 11: ...ightened further by to one turn maximum 6 Install the rotator control cable s round plug into the jack on the side of the rotator s base and tighten the connector ring to secure the connector Slide th...

Page 12: ...Figure 8 Figure 7 Figure 5 Figure 3 M8 16 length 16 mm Spring washer Thrust Bearing GS 065 option Must be parallel Antenna mast Provide sufficient slack More than 1 m Less than 1 m Mast Bearing GS 06...

Page 13: ...nstallation See your dealer for details of available lightning protection devices If an electrical storm should be reported in your area quickly unplug the control cable from the rear of the rotator s...

Page 14: ...NOTE 12...

Page 15: ...Copyright 1998 Yaesu Musen Co Ltd All rights reserved No portion of this manual may by reproduced without the permission of Yaesu Musen Co Ltd...

Reviews: