P
AGE
2
G-5500 Antenna Azimuth-Elevation Rotators & Contoroller Instruction Manual
SPECIFICATIONS
Voltage requirement
:
110-120 or 200-240 VAC
Motor voltage
:
24 VAC
Rotation time
(approx., @60Hz): Elevation (180°): 67 sec.
Azimuth (360°): 58 sec.
Maximum continuous operation
: 5 minutes
Rotation torque
:
Elevation: 14 kg-m (101 ft-lbs)
Azimuth: 6 kg-m (44 ft-lbs)
Braking torque
:
Elevation: 40 kg-m (289 ft-lbs)
Azimuth: 40 kg-m (289 ft-lbs)
Vertical load
:
200 kg (440 lbs)
Pointing accuracy
:
±4 percent
Wind surface area
:
1 m
2
Control cables
:
2 x 6 conductors - #20 AWG or larger
Mast diameter
:
38-63 mm (1-1/2 to 2-1/2 inches)
Boom diameter
:
32-43mm (1-1/4 to 1-5/8 inches)
Weight
:
Rotators: 9 kg (20 lbs)
Controller: 3 kg (6.6 lbs)
UNPACKING & INSPECTION
When unpacking the rotator confirm the pres-
ence of the following items:
Elevation Rotator Unit ................................. 1
Azimuth Rotator Unit .................................. 1
Controller Unit ............................................. 1
Mast Clamp (pair) ........................................ 2
Pipe clamp ................................................... 2
U Bracket ..................................................... 1
M8 x 16 Hex. Bolt ....................................... 4
M8 x 25 Hex. Bolt ....................................... 8
M8 x 70 Hex. Bolt ....................................... 4
M8 x 95 Hex. Socket Bolt ........................... 1
U-Bolt .......................................................... 2
6mm Spring Washer .................................... 4
6mm Flat Washer ......................................... 4
8mm Spring Washer .................................. 18
8mm Flat Washer ....................................... 12
M8 Square Nut............................................. 1
M8 Hex. Nut ................................................ 4
M6 Hex. Nut ................................................ 4
8-pin DIN Plug ............................................ 1
7-pin Metal Connector ................................. 2
Water Resist Cap ......................................... 2
Spare Fuse (117V:2A, 220V:1A) ................. 1
Instruction Manual ....................................... 1
If any of these items are missing or appear to
be damaged, save the carton and packing ma-
terial and notify the shipping company (or
dealer, if purchased directly at his shop).
Before proceeding with installation, confirm
that the AC voltage label on the rear of the
Controller matches your local line voltage: ei-
ther “117V” for 110 to 120 VAC, or “220” for
220 to 240 VAC. If the labeled voltage range
does not match, return the controller to the
dealer from whom you purchased it (different
power transformers are installed for the differ-
ent voltage ranges).
Note that cable is not included with the rotator,
as the length must be determined case-by-case.
Contact your Yaesu dealer to obtain the length
of cable your installation requires. For runs of
over 100 feet, use #18 AWG instead of #20
AWG.