background image

VX-2500U Alignment, Page 4/4

Vertex Standard Co., Ltd.

CTCSS Modulation Level

Select band center frequency channel, with 151.4Hz CTCSS encode, and reduce the AF generator
injection to zero.

Key the transmitter and adjust by control commands for CTCSS deviation from the computer for
0.75kHz ± 0.05kHz deviation as indicated on the deviation meter.

DCS Modulation Level

Select band center frequency channel, with DCS 023 enabled, reduce the AF generator injection to
zero.

Key the transmitter and adjust by control commands for DCS deviation from the computer for 0.75kHz ±
0.05kHz deviation as indicated on the deviation meter.

Receiver

Set up the test equipment as shown for receiver alignment, and construct the audio test adapter as
described in the box below.

With the transceiver set to band center frequency channel, and the RF signal generator tuned to the
same frequency,

set the generator for ±3.0kHz deviation (for 25kHz steps) with 1kHz tone modulation,

and set the output level for 1µV at the antenna jack.

Adjust by control commands for tune from the computer for optimum SINAD, reducing signal generator
output level as necessary for proper meter deflection.

After the previous step, final signal generator level should be less than 0.25µV for 12dB SINAD.

Squelch Threshold

Select band center frequency channel, and the RF signal generator turned to the same frequency, set
the generator for ±3.0kHz deviation with 1kHz tone modulation, and set the output level for -8dBµ at the
antenna jack.

Adjust the squelch threshold level by control commands for squelch threshold from the computer so
that it just closes (

BUSY

 LED turns off).

Summary of Contents for VX-2500U

Page 1: ...ment are not covered by the warranty policy Also Vertex Standard must reserve the right to change circuits and alignment procedures in the interest of improved performance without notifying owners Under no circumstances should any alignment be attempted unless the normal function and operation of the transceiver are clearly understood the cause of the malfunction has been clearly pinpointed and an...

Page 2: ...mal equalization with the environment before alignment If possible alignments should be made with oscillator shields and circuit boards firmly affixed in place Also the test equipment must be thoroughly warmed up before beginning Before beginning connect the transceiver and PC using the VPL 1 programming cable as described in the EEPROM Programming chapter and downloads the EEPROM data from the tr...

Page 3: ...mitter and confirm about 1 0V on the voltmeter PLL Reference Frequency With the wattmeter dummy load and frequency counter connected to the antenna jack and select band center frequency channel key the transmitter and adjust TC1001 on the Main Unit if necessary so the counter frequency is within 100Hz of the channel center frequency for the transceiver version Transmitter Transmitter Output Power ...

Page 4: ...test adapter as described in the box below With the transceiver set to band center frequency channel and the RF signal generator tuned to the same frequency set the generator for 3 0kHz deviation for 25kHz steps with 1kHz tone modulation and set the output level for 1µV at the antenna jack Adjust by control commands for tune from the computer for optimum SINAD reducing signal generator output leve...

Reviews: