background image

FCC ID: K66VX-3200V-2

Alignment

5/6

Vertex Standard Co., Ltd.

Press [Enter] on “[2] VCO Deviation” to align VCO Deviation.
Select the Channel 1 in alignment range.
Adjust the AF generator output level to 388mVrms(-6dBm) at 1 kHz to the pin3 of the
J1502 (D-sub 9pin).
Press the [Space] key on the keyboard to activate the transmitter.
Press the [UP]/[DWN] key, as need, to set the VCO Deviation (Wide) to the following
specification, as indicated on the deviation meter.
When the desired deviation level is attained, press [Enter] to lock in the new data.
Select the Channel 2, and set the VCO Deviation (Narrow), same as Channel 1.

        VCO Deviation (Wide): 4.0[kHz](±0.1[kHz])
        VCO Deviation (Narrow): 2.0[kHz](±0.1[kHz])

- [3] REF Deviation

This parameter is used to align the REF Deviation.
Press [Enter] on “[3] REF Deviation” to align REF Deviation.
Select the Channel 1 in alignment range.
Adjust the AF generator output level to 388mVrms(-6dBm) at 100Hz to the pin3 of the
J1502.
Press the [Space] key on the keyboard to activate the transmitter.
Press the [UP]/[DWN] key, as need, to set the modulation wave as follows.
Press [Enter] to lock in the new data.
Select the Channel 2, and set the modulation wave, same as Channel 1.

         

OK

            

NG

             

NG

- [4] CTCSS Deviation

This parameter is used to align the CTCSS deviation.
Press [Enter] on "[4] CTCSS Deviation" to align CTCSS Deviation.
Select the Channel 1 in alignment range.
Press the [Space] on the keyboard to activate the transmitter, and injects a CTCSS test
tone.
Press the [UP]/[DWN] key, as need, to set the CTCSS Deviation (Wide) to the following
specification.
Press [Enter] to lock in the new data.
Select the Channel 2, and set the CTCSS Deviation (Narrow), same as Channel 1.

        CTCSS Deviation (Wide): 0.70[kHz](±0.1[kHz])
        CTCSS Deviation (Narrow): 0.35[kHz](±0.1[kHz])

- [5] DCS Deviation

This parameter is used to align the DCS deviation.
Press [Enter] on “[5] DCS Deviation” to align DCS Deviation.
Select the Channel 1 in alignment range.
Press the [Space] key on the keyboard to activate the transmitter, and injects a DCS
test tone.
Press the [UP]/[DWN] key, as need, to set the DCS deviation  (Wide) to the following
specification.
Press [Enter] to lock in the new data.
Select the Channel 2, and set the DCS deviation (Narrow), same as Channel 1.

Summary of Contents for VX-3200V

Page 1: ... specifications after replacing any faulty components Those who do undertake any of the following alignments are cautioned to proceed at their own risk Problems caused by unauthorized attempts at realignment are not covered by the warranty policy Also Vertex Standard reserves the right to change circuits and alignment procedures in the interest of improved performance without notifying owners Unde...

Page 2: ...at the ambient temperature be the same as that of the transceiver and test equipment and that this temperature be held constant between 20 and 30 C 68 86 F When the transceiver is brought into the shop from hot or cold air it should be allowed time to come to room temperature before alignment Whenever possible alignments should be made with oscillator shields and circuit boards firmly affixed in p...

Page 3: ...whilst switching on And it is operated by the alignment tool automatically During the alignment mode normal operation is suspended Use the alignment tool program running on PC PLL VCV Connect the positive lead of the DC voltmeter to the test point TP1007 VCV on the RF Unit as indicated in the figure and the negative lead to chassis ground Set the transceiver to the high band edge frequency channel...

Page 4: ... action of PTT MON UP DOWN is ignored All of the action is remote controlled by PC Menu of the tool 0 Common TX 0 Tx Power High This parameter is used to align TX High power Press Enter on 0 Tx Power High to align TX High power Select the Channel 1 in alignment range Press the Space key on the keyboard to activate the transmitter Press the UP DWN key as need to set the power output to the followin...

Page 5: ...mitter Press the UP DWN key as need to set the modulation wave as follows Press Enter to lock in the new data Select the Channel 2 and set the modulation wave same as Channel 1 OK NG NG 4 CTCSS Deviation This parameter is used to align the CTCSS deviation Press Enter on 4 CTCSS Deviation to align CTCSS Deviation Select the Channel 1 in alignment range Press the Space on the keyboard to activate th...

Page 6: ... alignment RX Tuning after ending Select the MID frequency channel in alignment range Set the SG output level to 0dBµ EMF and obey the message 1 Threshold NSQL This parameter is used to align the noise level in squelch Threshold It adjusts this alignment RX Tuning after ending Select the MID frequency channel in alignment range Set the SG output level to 8dBµ EMF and obey the message 2 RX Tune Thi...

Reviews: