background image

FCC ID: K66VX-3200V-2

Alignment

6/6

Vertex Standard Co., Ltd.

        DCS Deviation (Wide): 0.60[kHz](±0.1[kHz])
        DCS Deviation (Narrow): 0.30[kHz](±0.1[kHz])

The actual DCS deviation will increase around 20% based on the above alignment as
follows,

Actual DCS Deviation (Wide): 0.70[kHz]

        

Actual DCS Deviation (Narrow): 0.35[kHz]

[1]

 

Common RX

- [0] Tight NSQL

This parameter is used to align the noise level in squelch Tight.
It adjusts this alignment RX Tuning after ending.
Select the MID frequency channel in alignment range.
Set the SG output level to 0dB

µ

 EMF, and obey the message.

- [1] Threshold NSQL

This parameter is used to align the noise level in squelch Threshold.
It adjusts this alignment RX Tuning after ending.
Select the MID frequency channel in alignment range.
Set the SG output level to -8dB

µ

 EMF, and obey the message.

- [2] RX Tune

This parameter is used to align RX Tune.
Select the MID frequency channel in alignment range.
Set the SG output level to -7dB

µ

 EMF.

Pressing the [DWN] key, reduce the RX Tune Level and set the SINAD above 12dB.

Summary of Contents for VX-3200V

Page 1: ... specifications after replacing any faulty components Those who do undertake any of the following alignments are cautioned to proceed at their own risk Problems caused by unauthorized attempts at realignment are not covered by the warranty policy Also Vertex Standard reserves the right to change circuits and alignment procedures in the interest of improved performance without notifying owners Unde...

Page 2: ...at the ambient temperature be the same as that of the transceiver and test equipment and that this temperature be held constant between 20 and 30 C 68 86 F When the transceiver is brought into the shop from hot or cold air it should be allowed time to come to room temperature before alignment Whenever possible alignments should be made with oscillator shields and circuit boards firmly affixed in p...

Page 3: ...whilst switching on And it is operated by the alignment tool automatically During the alignment mode normal operation is suspended Use the alignment tool program running on PC PLL VCV Connect the positive lead of the DC voltmeter to the test point TP1007 VCV on the RF Unit as indicated in the figure and the negative lead to chassis ground Set the transceiver to the high band edge frequency channel...

Page 4: ... action of PTT MON UP DOWN is ignored All of the action is remote controlled by PC Menu of the tool 0 Common TX 0 Tx Power High This parameter is used to align TX High power Press Enter on 0 Tx Power High to align TX High power Select the Channel 1 in alignment range Press the Space key on the keyboard to activate the transmitter Press the UP DWN key as need to set the power output to the followin...

Page 5: ...mitter Press the UP DWN key as need to set the modulation wave as follows Press Enter to lock in the new data Select the Channel 2 and set the modulation wave same as Channel 1 OK NG NG 4 CTCSS Deviation This parameter is used to align the CTCSS deviation Press Enter on 4 CTCSS Deviation to align CTCSS Deviation Select the Channel 1 in alignment range Press the Space on the keyboard to activate th...

Page 6: ... alignment RX Tuning after ending Select the MID frequency channel in alignment range Set the SG output level to 0dBµ EMF and obey the message 1 Threshold NSQL This parameter is used to align the noise level in squelch Threshold It adjusts this alignment RX Tuning after ending Select the MID frequency channel in alignment range Set the SG output level to 8dBµ EMF and obey the message 2 RX Tune Thi...

Reviews: