VX-450 S
ERIES
O
PERATING
M
ANUAL
9
B
EFORE
Y
OU
B
EGIN
replace the Battery Holder by pressing down on
both sides of the Battery Holder, if necessary.
Referring to Figure 2, insert the DC plug from
the optional
PA-45
AC Adapter into the DC jack
on the rear panel of the
CD-49
Desktop Charger,
and then plug the
PA-45
AC Adapter into the
AC line outlet.
Insert the battery pack into the
CD-49
Desktop
Charger while aligning the slots of the battery
pack with the guides in the nest of the
CD-49
;
refer to the illustration at the right for details on
proper positioning of the battery pack. If charg-
ing with the transceiver attached, turn the trans-
ceiver off. The antenna jack should be at the left
side when viewing the charger from the front.
If the battery pack is inserted correctly, the LED
indicator will glow red. A fully-discharged bat-
tery pack will charge completely in 1.5 - 3.0 hours
(depending on the battery pack being charged).
When charging is completed, the LED indicator
will change to green.
Disconnect the battery pack from the
CD-49
Desktop Charger and unplug the
PA-45
AC
Adapter from the AC line outlet.
WARNING
Perform the battery charging where the ambient
tempera-ture range +5 °C to +35 °C. Charge out
of this range could cause damage to the battery
pack.
F
IGURE
2