VX-450 S
ERIES
O
PERATING
M
ANUAL
30
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
SQL
BEEP
BELL
LIGHT
KEY
DIAL
PTT
SCAN
DW
AF
VOX
TX SV
ENCR
REC
PLAY
Select the Squelch Threshold Level (–15 to +15)
Set the Beep ON / OFF
Set the Bell ON / OFF
(Bell engaged by sub-audible CTCSS/DCS)
Set the BUSY/TX LED and Lamp ON / OFF
Set the Key Lock function ON (Lock) / OFF (Free)
Set the DIAL Lock function ON (Lock) / OFF (Free)
Set the PTT Lock function ON (Lock) / OFF (Free)
Set the Scan status
OFF: Stop the Scan
ON: Start the Scan
GRP: Start the Group Scan
FM: Start the Follow-Me Scan
Set the Dual Watch ON / OFF
(same function as DW key)
Set the Minimum Volume level (000 to 255)
Set the VOX level
Set the TX Saver ON / OFF
Set the Encryption ON / OFF
(This menu will appear only when the Encryption
setting of the current channel is set to “Key ON”
or “Power ON”.)
ONE
: Enables recording one message (max. 120
seconds), and playback from the beginning
of the message.
ROL
: Enables recording whenever squelch
opens, and playback of the last 120 sec-
onds.
Set the priority audio on playback mode.
PLY
: Playback audio is higher priority than re-
ceived signal
SIG
: Received signal is higher priority than play-
back audio
D
ISPLAY
D
ESCRIPTION
Note
: The menu “14: REC Mode” and “15: Play Mode” will ap-
pear only when the Voice Recording Unit is installed.
U
SER
S
ET
M
ODE
The
VX-450
Series includes a “User Set (Menu)”
Mode which allows the user to define or configure
various settings, such as Beep On/Off, Squelch, etc.
To activate the “User Set (Menu)” Mode:
Press (or press and hold) the programmable key
assigned to the “
SET
” function.
Select the User Set Mode Item you wish to change
using the [
A
]
/
[
B
] keys, then use the [
SIDE-1
]
/
[
SIDE-2
] button to adjust the setting of the se-
lected item.
Press the [
D
] key to store the new configuration.
The display indicates “
- SET -
” briefly, then exits
to normal operation.
You may cancel the selection by pressing the [
C
]
key. The display indicates “
- CANCEL -
” briefly,
then exits to normal operation.