VX-8GE O
PERATING
M
ANUAL
26
R
EPEATER
O
PERATION
G
ENERAL
Repeater stations, usually located on mountaintops or other high locations, provide a dra-
matic extension of the communication range for low-powered hand-held or mobile trans-
ceivers. The
VX-8GE
includes a number of features, which make repeater operation simple
and enjoyable.
R
EPEATER
S
HIFTS
Your
VX-8GE
has been configured, at the factory, for the repeater shifts customary in
your country. For the 144 MHz band, this usually will be 600 kHz, while the 430 MHz
shift will be 1.6 MHz or 7.6 MHz.
Depending on the part of the band in which you are operating, the repeater shift may be
either downward (
) or upward (
),
and one of these icons will appear to
the right of the display frequency on
the LCD when repeater shifts have
been enabled.
A
UTOMATIC
R
EPEATER
S
HIFT
(
ARS
)
The
VX-8GE
provides a convenient Automatic Repeater Shift feature, which causes the
appropriate repeater shift to be automatically applied whenever you tune into the desig-
nated repeater sub-bands in your country. These sub-bands are shown below.
If the ARS feature does not appear to be working, you may have accidentally disabled it.
To re-enable ARS:
1.
Press and hold the
m
key for one second to enter the Set Mode.
2.
Rotate the
DIAL
knob to select Set Mode Item
69: RPT ARS
.
3.
Press the
m
key briefly to enable selection of this Set
Mode Item.
4.
Rotate the
DIAL
knob to select “
ON
”(to enable Automatic
Repeater Shift).
5.
When you have made your choice, press the
PTT
switch to
save the new setting and return to normal operation.
ARS-Repeater Subbands
2-m
145.6
145.8
70-cm
Euro Version 1
Euro Version 2
439.45
438.20
433.00
434.60
433.40
435.00
Summary of Contents for VX-8GE