VX-8GR/GE O
PERATING
M
ANUAL
145
S
ET
M
ODE
I
TEM
89: STEP FREQUENCY
Function
: Setting of the DIAL frequency steps.
Available Values
: AUTO / 5.0 / 6.25 / 8.33 / 10.0 / 12.5 / 15.0 / 20.0 / 25.0 / 50.0 / 100.0
kHz
Default
: AUTO (Step automatically changes according to operating frequency.)
Note
: 1) This Set Mode Item can select and set the Dial frequency steps to individual
memory channels when Memory Offset Tuning is enabled as shown on page 47.
2) 8.33 kHz steps are available only when receiving on the Air band.
3) 5.0 kHz steps are not available for use on 250 - 300 MHz, nor above 580 MHz.
S
ET
M
ODE
I
TEM
90: TIME SET
Function
: Sets the Clock time.
See page 107 for details.
S
ET
M
ODE
I
TEM
91: TONE FREQUENCY
Function
: Setting of the CTCSS Tone Fre-
quency
Available Values
: 50 standard CTCSS tones
Default
: 100.0 Hz
S
ET
M
ODE
I
TEM
92: TONE-SRCH MUTE
Function
: Enables/Disables the receiver au-
dio output while the Tone Search Scanner is
activated.
Available Values
: ON / OFF
Default
: ON
S
ET
M
ODE
I
TEM
93: TONE-SRCH SPEED
Function
: Selects the Tone Search Scanner speed.
Available Values
: FAST (2.5 tone/sec) / SLOW (1.25 tone/sec)
Default
: FAST (2.5 tone/sec)
S
ET
M
ODE
I
TEM
94: TOT
Function
: Setting of the TOT time
Available Values
: OFF / 0.5min - 10.0min (0.5min/step)
Default
: 3.0min (3 minutes)
The time-out timer shuts off the transmitter after a continuous transmission which is equal
to the programmed time.
S
ET
M
ODE
S
ET
M
ODE
S
ELECTION
D
ETAILS
CTCSS TONE FREQUENCY
(
Hz
)
67.0
69.3
71.9
74.4
77.0
79.7
82.5
85.4
88.5
91.5
94.8
97.4
100.0
103.5
107.2
110.9
114.8
118.8
123.0
127.3
131.8
136.5
141.3
146.2
151.4
156.7
159.8
162.2
165.5
167.9
171.3
173.8
177.3
179.9
183.5
186.2
189.9
192.8
196.6
199.5
203.5
206.5
210.7
218.1
225.7
229.1
233.6
241.8
250.3
254.1
–
–
–
–