VX-8GR/GE O
PERATING
M
ANUAL
161
R
ECEIVER
Circuit Type
:
Double-Conversion Superheterodyne
IF
:
1st:
47.25 MHz (A (Main) Band),
46.35 MHz (B (Sub) Band),
2nd: 450 kHz
Sensitivity
:
1.5 µV (TYP) for 10 dB SN (108-137 MHz @AM)
0.2 µV for 12 dB SINAD (137-140 MHz @NFM)
0.16 µV for 12 dB SINAD (140-150 MHz @NFM)
0.2 µV for 12 dB SINAD (150-174 MHz @NFM)
1.0 µV for 12 dB SINAD (174-222 MHz @NFM)
0.5 µV for 12 dB SINAD (300-350 MHz @NFM)
0.2 µV for 12 dB SINAD (350-400 MHz @NFM)
0.18 µV for 12 dB SINAD (400-470 MHz @NFM)
1.5 µV for 12 dB SINAD (470-540 MHz @NFM)
3.0 µV (TYP) for 12 dB SINAD (540-800 MHz @NFM)
1.5 µV (TYP) for 12 dB SINAD (800-999.90 MHz @NFM)
(Cellular Blocked)
Selectivity
:
12 kHz/35 kHz (–6dB/–60dB: NFM, AM)
AF Output
:
200 mW @ 8 Ohms for 10 % THD (@ 7.4 V DC)
400 mW @ 8 Ohms for 10 % THD (@ 13.8 V DC)
Specifications are subject to change without notice, and are guaranteed within the 144/430 MHz
amateur bands only.
Cellular Blocked per FCC rule Part 15.121, may not receive 900 MHz Amateur band.
The
VX-8GR/GE
allows connecting a computer COM port to the
DATA
Jack, and en-
ables the following functions. Refer to refer to “APRS/GPS Set Mode Item 15: COM
PORT SETTING” for the details.
Displays the location data (Lat/Lon) of the after-market GPS receiver on the dis-
play.
Outputs the location data (Lat/Lon) of the built-in GPS receiver unit.
Outputs the Waypoint data of the received APRS beacon.
Refer to the illustration below, connect the optional
CT-143
PC Connection Cable be-
tween the
COM
port of your Computer and the
DATA
Jack on the
VX-8GR/GE
.
S
PECIFICATIONS