VX-8R O
PERATING
M
ANUAL
139
S
ET
M
ODE
55: MEMORY SKIP
56: MEMORY WRITE
57: MESSAGE LIST
58: MESSAGE REGISTER
59: MESSAGE SELECT
60: MIC GAIN
61: MONI/T-CALL
62: MUTE
63: OFF TIMER
64: ON TIMER
65: OPENING MESSAGE
66: PAGER ANS-BACK
67: PAGER CODE-RX
68: PAGER CODE-TX
69: PASSWORD
70: PR FREQUENCY
71: PRI REVERT
72: PRI TIME
73: PTT DELAY
74: RPT ARS
75: RPT SHIFT
76: RPT SHIFT FREQ
77: RX AF DUAL
78: RX MODE
79: SAVE RX
80: SAVE TX
81: SCAN LAMP
82: SCAN RE-START
83: SCAN RESUME
84: SENSOR DISPLAY
85: SENSOR INFORMATION
86: SET MODE CSR
87: SET MODE FORMAT
88: SMART SEARCH
89: S-METER SYMBOL
90: SPEAKER OUT
91: SPEC-ANALYZER
92: SQL LEVEL
93: SQL S-METER
94: SQL SPLIT
95: SQL TYPE
96: STEP FREQUENCY
97: STEREO
98: TIME SET
99: TONE FREQUENCY
100: TONE-SRCH MUTE
101: TONE-SRCH SPEED
102: TOT
103: UNIT OFFSET
104: UNIT SELECT
105: VFO MODE
106: VFO SKIP
107: VOLUME MODE
108: VOX
109: VOX DELAY
110: WAVE MONITOR
111: WX ALERT
Selects the Memory Scan channel-selection mode.
Determines the method of selecting channels for Memory Storage.
Programming a Member List for the Message feature.
Selects your Personal ID for the Message feature.
Programming a Message for the Message feature.
Adjusts the microphone gain level.
Selects the
MONI
key (just below the
PTT
switch) function.
Adjusts the receiver audio output level when the MUTE function was activated.
Set the OFF Timer time.
Set the ON Timer time.
Selects the Opening Message that appears when the radio is powered on.
Enables/Disables the Answer Back function of the Enhanced CTCSS Paging & Code Squelch.
Sets the Receiver Pager Code for the Enhanced CTCSS Paging & Code Squelch.
Sets the Transmitting Pager Code for the Enhanced CTCSS Paging & Code Squelch.
Programming and activating the Password feature.
Program the CTCSS Tone Frequency for the User Programmed Reverse CTCSS Decoder.
Enables/Disables the Priority Revert feature.
Selects the time between the Priority (Dual Watch) channel checks, when the feature is
active.
Selects the time delay before the carrier is transmitted, when the
PTT
switch is pressed.
Enables/Disables the Automatic Repeater Shift function.
Sets the Repeater Shift Direction.
Sets the magnitude of the Repeater Shift.
Select the resume mode of the AF-Dual Operation.
Sets the receiving mode.
Selects the Receive-mode Battery Saver interval (“sleep” ratio).
Enables/Disables the Transmitter Battery Saver.
Enables/Disables the Scan Lamp (while scanner is paused).
Selects the Scan Re-start Delay time.
Selects the Scan Resume mode.
Selects the sensor information when the transceiver is operating in the “Mono” band mode
with large characters.
Indicates the Information of the internal sensors.
Selects the Set Mode Cursor.
Selects the display format of the Set Mode operation.
Selects the Smart Search Sweep mode.
Selects the S- & TX PO meter Symbol.
Enables/Disables the FM Broadcast audio output to the internal speaker when using the
earphone antenna.
Selects the Spectrum Analyzer sweep mode.
Sets the Squelch threshold level.
Adjusts the Squelch threshold level to the S-meter level.
Enables/disables split CTCSS/DCS coding.
Selects the Tone Encoder and/or Decoder mode.
Setting of the DIAL frequency steps.
Enables/Disables the stereo output while receiving the FM Broadcast band.
Sets the Clock time.
Setting of the CTCSS Tone Frequency
Enables/Disables the receiver audio output while the Tone Search Scanner is activated.
Selects the Tone Search Scanner speed.
Setting of the TOT time
Correcting the Sensor Unit.
Select the measurement units of the Sensor Unit.
Selects or disables the VFO band edge limiting for the current band.
Setting My Band.
Select the [
VOL
] key function.
Enables/Disables VOX operation; sets VOX sensitivity.
Selects the VOX delay (“hang”) time.
Selects the Wave-Form display while indicating the Wave-Form via Set Mode Item 84: SEN-
SOR DISPLAY.
Enables/Disables the Weather Alert Feature
OFF
/ SKIP / ONLY
NEXT
/ LOWER
--
--
--
LEVEL 1 ~ LEVEL 9 (
LEVEL 5
)
MONI / T-CALL
Ú
1
MUTE 30%, MUTE 50%,
MUTE 100%, or
OFF
--
--
NORMAL
/ OFF / DC / MESSAGE
ON /
OFF
--
--
--
300Hz ~ 3000Hz (1000Hz/step) (
1600Hz
)
ON /
OFF
0.1sec ~ 0.9sec (0.1sec/step) or
1.0sec ~ 10.0sec (0.5sec/step) (
5.0sec
)
OFF
/ 20ms / 50ms / 100ms / 200ms
ON
/ OFF
SIMPLEX
/ -RPT / +RPT
0.000MHz ~ 150.000MHz (50 kHz/step)
Ú
2
TRX 1sec ~ TRX 10sec / HOLD /
TX 1sec ~ TX 10sec (
TRX 2sec
)
AUTO
/ N-FM / AM / W-FM
0.2sec
~ 0.9sec (0.1sec/step) or
1.0sec ~ 10.0sec (0.5sec/step)
ON /
OFF
ON
/ OFF
0.1sec ~ 0.9sec (0.1sec/step) or
1.0sec ~ 10.0sec (0.5sec/step) (
2.0sec
)
2.0sec ~ 10.0sec (0.5sec/step) /BUSY /
HOLD (
5.0sec
)
DC
/ TEMP / WAVE / BARO / ALTI / OFF
--
Nine patterns
LIST
/ ITEM
SINGLE
/ CONTINUOUS
Four patterns
AUTO
/ SPEAKER
1Time
/ CONTINUOUS / Full Time
LEVEL 0 ~ LEVEL 15 (
LEVEL 1
)
(AM and Narrow FM),
LEVEL 0 ~ LEVEL 8 (
LEVEL 2
)
(Wide FM and AM Broadcast)
OFF
/ LEVEL 0 ~ LEVEL 9
OFF
/ ON
OFF
/ TONE / TONE SQL / DCS /
REV TONE / PR FREQ / PAGER / MESSAGE
AUTO
/ 5.0 / 6.25 / 8.33 / 9.0 / 10.0 / 12.5 /
15.0 / 20.0 / 25.0 / 50.0 / 100.0 kHz
STEREO
/ MONO
--
50 standard CTCSS tones (
100.0Hz
)
ON
/ OFF
FAST
(2.5 tone/sec) / SLOW (1.25 tone/sec)
OFF / 0.5min ~ 10.0min (0.5min/step)
(
3.0min
)
--
TEMP: °C / °F
Ú
1
BARO: HPA / mb / mmHg / inch
ALTITUDE: m / ft
ALL /
BAND
--
NORMAL
/ AUTO BACK
OFF
/ HIGH / LOW
0.5sec
/ 1.0sec / 1.5sec /
2.0sec / 2.5sec / 3.0sec
ALL
/ RX SIGNAL / TX MODULATION
ON /
OFF
S
ET
M
ODE
I
TEM
F
UNCTION
A
VAILABLE
V
ALUES
(
D
EFALT
: U
NDERLINED
B
OLD
)
Ú
1: Depends on the transceiver version.
Ú
2: Depends on the operating band and transceiver version.
Summary of Contents for VX-8R
Page 61: ...VX 8R OPERATING MANUAL 59 NOTE ...
Page 77: ...VX 8R OPERATING MANUAL 75 NOTE ...