VX-8R O
PERATING
M
ANUAL
69
“P
RIORITY
C
HANNEL
” S
CANNING
(
D
UAL
W
ATCH
)
The
VX-8R
’s scanning features include a two-channel scanning capability which allows
you to operate on a VFO or Memory channel, while periodically checking a user-defined
Memory Channel for activity. If a station is received on the Memory Channel which is
strong enough to open the Squelch, the scanner will pause on that station in accordance
with the Scan-Resume mode set via Menu Item
83: SCAN RESUME
83: SCAN RESUME
83: SCAN RESUME
83: SCAN RESUME
83: SCAN RESUME
. See page 60.
Here is the procedure for activating Priority Channel Dual Watch operation:
1. Press the
key briefly to enter the Memory Recall (“MR”) mode, if you are not
using memories already.
2. Press and hold in the
key for one second, then rotate the
DIAL
knob to select the
memory channel you wish to be the “Priority” channel.
3. Press the
key. The “
P
P
P
P
P
” icon will appear to the right of
the “
MR
MR
MR
MR
MR
” label, indicating it is the Priority channel.
4. Now set the
VX-8R
for operation on another memory chan-
nel, or on a VFO frequency.
5. Press and hold in the
key for one second. The display
will remain on the VFO or memory channel selected. How-
ever, every five seconds the
VX-8R
will check the Priority
Channel for activity. The “
MR
MR
MR
MR
MR
” label will be replaced by
“
MDW
MDW
MDW
MDW
MDW
” while operating on the Memory channel or the “
VFO
VFO
VFO
VFO
VFO
” label will be replaced
by “
VDW
VDW
VDW
VDW
VDW
” while operating on the VFO mode.
6. If a station appears on the Priority Channel, the radio will pause on that channel, as
described previously.
The receiving time interval (ratio) between the current channel (or VFO frequency) and
Priority channel may be customized via Set Mode Item
72: PRI TIME
72: PRI TIME
72: PRI TIME
72: PRI TIME
72: PRI TIME
.
To set the receiving time interval:
1. Press and hold the
key for one second to enter the Set Mode.
2. Rotate the
DIAL
knob to select Set Mode Item
72: PRI TIME
72: PRI TIME
72: PRI TIME
72: PRI TIME
72: PRI TIME
.
3. Press the
key briefly to enable adjustment of this Set
Mode Item.
4. Rotate the
DIAL
knob to select the desired time interval.
Available selections are
0.1sec
0.1sec
0.1sec
0.1sec
0.1sec
-
0.9sec
0.9sec
0.9sec
0.9sec
0.9sec
(0.1sec/step) and
1.0sec
1.0sec
1.0sec
1.0sec
1.0sec
-
10.0sec
10.0sec
10.0sec
10.0sec
10.0sec
(0.5sec/step).
5. Press the
PTT
switch briefly to save the new setting and
exit to normal operation.
The default condition for this Set Mode Item is “5.0sec”.
S
CANNING
Summary of Contents for VX-8R
Page 61: ...VX 8R OPERATING MANUAL 59 NOTE ...
Page 77: ...VX 8R OPERATING MANUAL 75 NOTE ...