background image

1

-

DESCRIPTION

Central Heating Stove

with Fireplace

is

the

Models

with oven

(301)

also makes cooking.

system

that burns wood and

coal loaded in

it

with

302

model which

produces hot

utility water

has

the aid of lighters such

as

kindling wood and

paper;

hot water

production

and instant heating system.

and

then

delivers the

occurring

heat

to

the

water

taking

place within the boiler and

conveys

the

same

to

all

points of the configuration.

Central

Heating

Stove

with Fireplace also convects

from

its surrounding.

RE-FUELLING INTERVALS

Burning

Condition

Fuel

Type

Re-Fuelling Interval

Nominal

6.000

kcal/hour

coal

5

hours

Slow

6.000

kcal/hour

coal

12

hours

EXHAUST GAS

TEMPERATURE

Exhaust Gas temperature is 200°C

average.

Technical

 

Specifications

Product

 

Code

Capacity
Fuel

 

Type

Smoke

 

Pipe

 

Diameter

 

Boiler

 

Inlet

 

Outlet

 

Pipe

Fuel

 

Capacity

Electricity

Pump

 

Power

Net

 

Weight

Width/Depth/Height

 

301

16  /  25

 

kW.

 

 

 
 

 

13

 

cm

R1”

15

 

kg

 

 

 

 
   

46-93

 

W

150

 

Kg

 

 

302

16  /  25

 

kW

  

Wood

-

Coal    

 

W

ood-Coal

 
 

 

13

 

cm

R1”

  

15

 

kg

 

 

 

 
    
 

   

46-93

 

W

 

120

 

Kg

 

401

16

 

/

 

25 kW

 

Wood-Coal 
13 cm
R1”
15 kg

 

46-93 W

 

175 Kg

220

 

V

 

/

 

50

 

Hz.

 

220

 

V

 

/

 

50

 

Hz.

 

220 V / 50 Hz.

 

220 V / 50 HZ.

46-93 W

 

70 Kg

58x54x110

 

cm

 

48x66x86

 

cm

 

63x106x73 cm

 

49

x5

4

x

70

 cm

303

16  /  25 kW

Wood-Coal 
13 cm
R1”
15 kg

Summary of Contents for 301

Page 1: ...OPERATING MANUAL Please do not use your Central Heating Stove before reading this manual with Fireplace Stoveand Solic Fuel cc MODEL NO English ...

Page 2: ...We thank you for choosing Yakar Products You will always obtain maximum output When you read this Operating Manual prepared to assist you and as long as you comply with the instructions in it ...

Page 3: ... THE LOCATION TO PLACE AND INSTALLATION INSTRUCTIONS 4 5 ELECTRICAL DIAGRAM 6 301 and 302 INSTALLATION CONNECTION DIAGRAM 7 OPERATING CENTRAL HEATING STOVE 8 WARNING and RECOMMENDATIONS 9 CHIMNEYS and POINTS TO TAKE INTO CONSIDERATION 10 PROBLEMS and SOLUTION PROPOSALS 11 12 POINTS TO TAKE INTO CONSIDERATION FOR THE GUARANTEE 13 ...

Page 4: ...rrounding RE FUELLING INTERVALS Burning Condition Fuel Type Re Fuelling Interval Nominal 6 000 kcal hour coal 5 hours Slow 6 000 kcal hour coal 12 hours EXHAUST GAS TEMPERATURE Exhaust Gas temperature is 200 C average Technical Specifications Product Code Capacity Fuel Type Smoke Pipe Diameter Boiler Inlet Outlet Pipe Fuel Capacity Electricity Pump Power Net Weight Width Depth Height 301 16 25 kW ...

Page 5: ... Rear Housing Lid 15 Riaht Housina Lid 14 Lef Housing Lid 13 Ashtray 12 Oven Glass 11 Cleaning the cover from the too 10 Lid Hamdle 9 Bottom Lid 8 Ceramic Glass 7 Middle Lid 6 Oven Lid 5 Pull And Dump Handle 4 Turninq Handle 3 Pull And Dump 2 Rotary 1 Bowl Grid Figure 1 ...

Page 6: ... with conic pipe couplings 2 12 Steam exit taking place on the expansion tank must be extended to restroom bathroom or to ventilation medium 2 13 Main line pipes of the installation must be R1 one finger Horizontal pipes for the final cores are selected as R 3 4 2 14 Very good heat insulation must be done for the pipes passing from the concrete floor Otherwise adequate heat can not be obtained fro...

Page 7: ...r Outlet 9 Water Flow Back To Boiler 10 Indicator Light 11 Thermometer thermostat 12 Water Level Indicator 13 herald steam dispose 14 steam outlet Make the installation of radiator heaters to structure with Conical Record so that the installation and dismantling would be easier During the installation we connect the water to boiler at 09 from the water line Expansion Boiler Figure 2 Installation c...

Page 8: ... be turned once with the screwdriver Big yellow screw is applied to its place when shaft starts to turn 3 6 Air of the cores must be removed Water level of expansion tank must be controlled 3 7 Water is given to the system from boiler s inlet pipe Figure 2 9 from service water line 3 8 After becoming sure that there is no leakage in the system fuel is loaded to the firing chamber and then the fire...

Page 9: ...te COKE Mix with Lignite with 1 3 rate WOOD Hu Hu Hu Hu Hu Hu Hu Hu 6650 7900 6500 7000 3200 4500 2500 3200 1100 2500 7000 7300 4500 5500 2000 3500 Kcal h Kcal h Kcal h Kcal h Kcal h Kcal h Kcal h Kcal h a Good Draft b Average Draft c Bad DraftCeki CHIMNEYS and POINTS TO TAKE INTO CONSIDERATION Pipes of Central Heating Stove must be as short and they must be in vertical direction as much as possib...

Page 10: ...mmended one bracket FALSE RIGHT Figure 7 Expansion Connection Yanh Yanh Dogru Yanh Yanh Figure 6 Chimney Connection Expansion must be connected to boiler at least 1 degree incline s Figure 7 The roof ridge must be at least 80cm also smoke outlet should be through the window as well as If there is ash drawer it should be canceled Figure 8 Figure 8 Pipe and chimney connection ...

Page 11: ...ll and roof insulation must be done 4 This problem disappears after burning for a certain period of time and after the walls get warm LAST CORE IS NOT GETTING WARM 1 Horizontal pipe coming to the last core has been used as small R 1 2 2 Spout has occurred towards the inside at the source of plastic pipe and cross section of the pipe has been narrowed 1 Increase the revolution of the pump If not so...

Page 12: ...o either one of the seller dealer representative importer or manufacturer producer of the product when there is no service station If the malfunction of the product can not be eliminated within 30 Thirty days then the manufacturer producer or importer has the compulsion to allocate another product to the consumer by having similar characteristics until the repair of the products gets completed 4 I...

Page 13: ......

Page 14: ... the boiler water reach 70 90 C hot utility water can be obtained for a long period of time 6 HOW IS YOUR FURL COMBUSTION QUALITY In a good combustion after ignition and inflammation stage flame becomes red or orange color Glowing coal becomes eye popping brilliant In a weak combustion top surface of the coal is black during combustion and when the combustion ends some part of the coal remains unb...