Appendix ES2 Series Servo User Manual Lite V1.0
50
P07 group: gain parameter
Function
code
Name
Setting range
Min.
unit
Default
setting
Effective
time
Type
Mode
P07
00
Position loop gain 1
1
~
2000.0
0.1HZ 320
Effective
immediate
ly
Set
when
runnin
g
P
P07
01
Speed loop gain 1
1
~
2000
0.1HZ 180
Effective
immediate
ly
Set
when
runnin
g
PS
P07
02
Speed loop integral
time 1
15
~
51200
0.01m
s
3100
Effective
immediate
ly
Set
when
runnin
g
PS
P07
03
Speed
detection
filter 1
0
~
200
0.01m
s
60
Effective
immediate
ly
Set
when
runnin
g
PST
P07
04
Torque
command
filtering 1
126~65535
0.01m
s
126
Effective
immediate
ly
Set
when
runnin
g
PST
P07
05
Position loop gain 2
1
~
2000.0
0.1HZ 380
Effective
immediate
ly
Set
when
runnin
g
P
P07
06
Speed loop gain 2
1
~
2000
0.1HZ 180
Effective
immediate
ly
Set
when
runnin
g
PS
P07
07
Speed loop integral
time 2
15
~
51200
0.01m
s
51200
Effective
immediate
ly
Set
when
runnin
g
PS
P07
08
Speed
detection
filter 2
0
~
200
0.01m
s
0
Effective
immediate
ly
Set
when
runnin
g
PST
P07
09
Torque
command
filtering 2
126~65535
0.01m
s
126
Effective
immediate
ly
Set
when
runnin
g
PST
P07
10
DI function GAIN-
SWITCH switching
action selection
0-speed loop
regulator P (1) / PI
(0) switch, gain is
fixed to first group
1-first gain (0),
second gain (1)
switching
1
0
Effective
immediate
ly
Set
when
runnin
g
PS