background image

Retrofitting or modifying this product may impact fire rating, safety features and warranty. 

Consult with code specifications to ensure compliance with all codes and ratings.

nex

Touch

 Keypad Access Cylindrical Lock

Touchscreen and Push Button

Installation and Programming Instructions

AA

AA

AA

AA

Optional

3/32"

Optional

80-9150-0080-010   11-21

Part of ASSA ABLOY

Summary of Contents for nexTouch

Page 1: ...and warranty Consult with code specifications to ensure compliance with all codes and ratings nexTouch Keypad Access Cylindrical Lock Touchscreen and Push Button Installation and Programming Instructions AA AA AA AA Optional 3 32 Optional 80 9150 0080 010 11 21 Part of ASSA ABLOY ...

Page 2: ...he term secure means the side from which you initially unlock and enter Left Hand LH Hinges Left Open Inward Left Hand Reverse LHR Hinges Left Open Outward Right Hand RH Hinges Right Open Inward Right Hand Reverse RHR Hinges Right Open Outward 2 80 9150 0080 010 11 21 Part of ASSA ABLOY ...

Page 3: ... side to prevent splitting DPS Option Wood Door 3 8 Dia Thru to Hole in Door Face Metal Door 3 4 Dia Thru to Hole in Door Face Metal Door Installations Supplied plastic collar MUST be installed for DPS to function properly 1 3 80 9150 0080 010 11 21 Part of ASSA ABLOY ...

Page 4: ...oor Frame 3 1 2 DPS Option Wood Frame 3 8 Dia x 1 Metal Frame 3 4 Dia x 1 See Instruction A7983B 7 16 8 32 x 1 UNCWS x2 Metal Door Installations Supplied plastic collar MUST be installed for DPS to function properly 2 4 80 9150 0080 010 11 21 Part of ASSA ABLOY ...

Page 5: ...Prepare Inside Lock Do not take apart the keypad 3 2 1 3 5 80 9150 0080 010 11 21 Part of ASSA ABLOY ...

Page 6: ... faces direction door closes Install Latchbolt Inside of Door 7 16 8 32 x 1 UNCWS x2 2 3 8 Latchbolt for thin doors sold separately See Installation Options Remove Battery Cover 4 5 6 80 9150 0080 010 11 21 Part of ASSA ABLOY ...

Page 7: ...ting Flange Two moving T tabs must be fully captured in retractor pocket Mounting Flanges must be in Mounting Flange Pockets Mounting Flange Pocket Mounting Flange Mounting Flange Pocket Thin door gaskets sold separately See Installation Options Optional DPS 6 7 80 9150 0080 010 11 21 Part of ASSA ABLOY ...

Page 8: ...10 32 x 2 1 2 PFHMS Install Inside Support x2 Do Not Overtighten Screws Inside of Door Optional DPS 7 8 80 9150 0080 010 11 21 Part of ASSA ABLOY ...

Page 9: ...Attach Cables to Inside Lock Optional DPS Connection Motor Connection Keypad Connection 8 9 80 9150 0080 010 11 21 Part of ASSA ABLOY ...

Page 10: ...Install Inside Lock Test Inside Lever Operation Avoid Crimping Cables Thin door gaskets sold separately See Installation Options 9 10 80 9150 0080 010 11 21 Part of ASSA ABLOY ...

Page 11: ...nal Network or Yale Accentra Key module must be installed BEFORE batteries See Installation Options Welcome to Yale Congratulations you ve installed the Yale nexTouch Cylindrical Lock 10 11 80 9150 0080 010 11 21 Part of ASSA ABLOY ...

Page 12: ...nction properly O optional Inside Gasket Outside Gasket CAUTION Cylinders furnished with nexTouch lock for use in 1 3 8 doors have a tailpiece that is 1 4 shorter than the standard cylinders that are furnished for 1 3 4 doors Trying to install a standard cylinder in 1 3 8 door will DAMAGE the lock 2 3 8 Latchbolt 12 80 9150 0080 010 11 21 Part of ASSA ABLOY The Yale Accentra Key module enables acc...

Page 13: ...chscreen Keypad 9Volt Battery Override Terminal Lockout Mode Indicator Touchscreen Unlock Indicator Touchscreen Lock Activation Touchscreen Press Yale logo Touch keypad with whole hand Press check key Lock Activation Push Button Press any key 13 80 9150 0080 010 11 21 Part of ASSA ABLOY ...

Page 14: ... PIN code Press the gear key to continue Registered Completed Creating Master PIN Code 1 Creating a Master PIN Code must be performed upon installation or after resetting the lock to factory default Programming and use of lock is not possible until this step has been successfully completed 14 80 9150 0080 010 11 21 Part of ASSA ABLOY ...

Page 15: ...egister User code Press the gear key to continue Press Press Register User code Press the gear key to continue PIN code registration Enter a 4 8 digit PIN code Press the gear key to continue 15 80 9150 0080 010 11 21 Part of ASSA ABLOY The Yale Accentra Key module enables access with physical cards and fobs and mobile credentials ONLY Creation and use of User PIN codes are disabled 2a ...

Page 16: ... code Press To end programming Press Registered Press the check key to complete Press the gear key to continue Enter 4 8 digit PIN code followed by Completed Registered Press the check key to complete Press the gear key to continue 16 80 9150 0080 010 11 21 Part of ASSA ABLOY 2b ...

Page 17: ...a Key module enables access with physical cards and fobs and mobile credentials ONLY Creation and use of User PIN codes are disabled Master PIN code is only used for programming and configuring lock with Yale Accentra Multi Family configuration app and will not unlock door When lock is configured into Accentra 2 and 6 will no longer be visible when in menu mode ...

Page 18: ...4 Testing Outside Lever Operation Locking Door with Privacy Button 18 80 9150 0080 010 11 21 Part of ASSA ABLOY ...

Page 19: ...n temporarily remove one 1 AA battery 9 Reinstall the battery 10 Release reset button and wait approximately 15 seconds Speaker will announce Welcome to Yale 11 Reassemble inside lock and lever 12 If utilizing a network module remove batteries Insert module Reinstall batteries Inside Lock When lock is reset to factory defaults all PIN codes including the Master PIN code are deleted and all program...

Page 20: ...or when Automatic Re lock is disabled When One Touch Re lock is not in use disabled any valid PIN code will re lock the lock Main Menu selection 3 then 3 Passage PIN Code When used to unlock lock will remain unlocked open Lock cannot be locked secured until Passage code is entered again Privacy Button to Lock Door A press of this button will lock the door Privacy Mode With optional Door Position S...

Page 21: ...U User Code Passage Code Continue Complete U Delete A Code Join the network Exit the network 1 Activate the lock 2 Enter 4 8 digit master PIN code followed by key Lock Response Menu mode enter number Enter digit corresponding to the function to be performed press the key to continue 3 Follow the voice commands 4 Press key to complete the process and conclude the programming session The Master PIN ...

Page 22: ... PIN code may already be registered Batteries do not have enough power Replace batteries Check that cables are fully connected on inside lock and not crimped Replace batteries Touchscreen models become active by pressing Yale logo or key or by touching keypad with whole hand Push Button models become active when any key is pressed The digits entered were incorrect or incomplete Re enter 4 8 digits...

Page 23: ...et Look through 2 1 8 hole and verify latchbolt tail is centered between top and bottom of hole b Remove latchbolt and insert lockset Look through latchbolt hole and verify retractor mouth is centered in hole If not adjust outside rose plate c If necessary rebore holes to line up retractor and tail Door is binding a Check that door and frame are properly aligned and door is free swinging b Check h...

Page 24: ...itten permission of ASSA ABLOY Access and Egress Hardware Group Inc is prohibited Industry Canada This device contains licence exempt transmitter s receiver s that comply with Innovation Science and Economic Development Canada s licence exempt RSS s Operation is subject to the following two conditions 1 This device may not cause interference 2 This device must accept any interference including int...

Reviews: