YDV4202-V1
•
Lock Control Jumper: Not to be removed
•
Doorstation Code DIP: To be used when additional exterior units are used in the same system.
•
Main Connect Port: To connect the interior monitor and electornic lock/s.
BUS: Connection to interior monitor, no polarity.
PL: External lock power input, connect to the power positive(power +).
S1+, S2+: Lock power(+) output. To locks can be connected through the unit.
S-: Lock power(-) output, connect to the power(-) input of locks only when using the camera to
power the locks, if using the external power supply for the locks, the S- will not be connected).
Lock Power supply:
12Vdc, 300mA(Internal Power)
Power Consumtion:
1W in standby, 12W in working
NO, COM dry contact:
Max. 48V dc 1.5A
Unlocking time:
1 to 9 seconds, set by Monitor
Working temperature:
-10ºC ~ 45ºC
3. Specification
4.Mounting
160-165cm
1
2
1
2
3