Dummy Trim

See Interior Mechanism Housing Installation

Page 3 For Installation Instructions

P/N 80-9510-0056-010 Rev B

REMOVAL OF CYLINDER
When not installed on door

REMOVAL OF CYLINDER
When installed on door

Remove the loose plate from the
back of the cylinder. Two screws
hold a metal strap in place. Under
the “C” cutout in this strap is a
semicircular indention in a spring
loaded tab. Using the cylinder
removing tool (wire with loop) or a
screwdriver, place the tip of the tool
against the tab in the indention and
push toward the center and then
clockwise. The purpose is to move

the cylinder and strap to the left.
When all the way left, push the
cylinder out of the housing.
Note: it may be necessary to put
the tool in between the gap created
on the right and force the cylinder
to the left. Remove the plug
assembly from the cylinder housing
for re-keying.

Insert the key into the plug. Press
the
cylinder removing tool into the hole
positioned at 5 o’clock and turn the
key counterclockwise. This will
cause the face of the cylinder to
rotate to the left slightly. Once
turned off center, pull on the key to
remove the cylinder. Remove the
plug assembly from the cylinder
housing for re-keying.

Summary of Contents for 4800LN

Page 1: ...LATION INSTRUCTIONS Installation of this product requires that two 2 1 8 holes are spaced 4 apart center to center See the hole template sheet for accurate hole locations Interior Mechanism Housing Connecting Screws Installation Plate Latch Deadbolt Latch Deadbolt Hub with Square Spindle Tailpiece ...

Page 2: ...n then tighten all four connecting screws Reinstall the interior mechanism housing on the installation plate with the two self thread screws saved before Once this operation is done the square spindle for the interior mechanism housing is inside the hub of the lower latch and operates the latch Note that the thumbturn must be in the vertical position then slide the lever over the bottom tube and p...

Page 3: ...mm hole halfway through door Finish bore from other side to prevent splintering 4 To mark strike location close the door and push locator pin through both guide holes marking the strike plates center position 5 Bore 2 holes 1 25mm through the door edge 6 For handleset installation only Bore 5 16 hole to receive bottom portion of handleset 7 Insert the latch and then trace outlines of latchplates C...

Page 4: ...ctions P N 80 9510 0056 010 Rev B REMOVAL OF CYLINDER When not installed on door REMOVAL OF CYLINDER When installed on door Remove the loose plate from the back of the cylinder Two screws hold a metal strap in place Under the C cutout in this strap is a semicircular indention in a spring loaded tab Using the cylinder removing tool wire with loop or a screwdriver place the tip of the tool against t...