Exit Device Shim Kits

Installation Instructions

Shim Locations

#724, 724WS, 724NS, and 224 Shim Kits for
Surface Vertical Rod Exit Devices

Vertical Latch Shim 

60-7010-1060-200

Rod Guide Shim 

60-7010-1065-200

Device Shim

Standard
60-7100-1004-200

2100/1800 and
Narrow Stile
60-7000-1106-200

Device Shim

Standard
60-7100-1004-200

2100/1800 and
Narrow Stile
60-7000-1106-200

Device End Cap Shim

7000 Series - 60-7000-1107-200
2100/1800 Series - 60-2000-1181-200

Device End Cap Shim       

7000 Series - 60-7000-1107-200

2100/1800 Series - 60-2000-1181-200

#723, 723WS, 723NS, 723NSWS, and 223 Shim Kits
for Rim, Mortise, & CVR Exit Devices

Note:

 Use shim in addition

to the Latch Mounting Plate.
Top and Bottom.

Notes:

1. Each standard shim kit contains 2 sets of
    1/8" thick shims.  Windstorm (WS) shim kits
    contain 3 sets of 1/8" thick shims.

2. Place shims, as required. Use (1) shim 
    for each 1/8" (3mm) of device lift needed.
    

When mounting the device, position shims 

    as shown, using the installation instructions
    packed with the unit.

 Use longer screws

    provided.

3. For Concealed Vertical Rod Device
    see yoke pin shim location per illustration
    on page 2.

1

2

Attention Installer

Any retrofit or other field modification to a fire rated opening can 
potentially impact the fire rating of the opening, and Yale Locks & 
Hardware makes no representations or warranties concerning 
what such impact may be in any specific situation.  When 
retrofitting any portion of an existing fire rated opening, or 
specifying and installing a new fire-rated opening, please consult 
with a code specialist or local code official (Authority Having 
Jurisdiction) to ensure compliance with all applicable codes and 
ratings.