30
Commands Communication Timing
The following are the commands and total times that the Z-Wave System needs to
be aware of when interacting with our ZW3 Locks before sending next commands:
Table 13
–
Event vs Process Time
Commands/Events
TOTAL TIME
Door Lock Operation Get
40 milliseconds
Door Lock Operation Set (RF Unlock/Lock) ¹ 2.674 seconds
Door Lock Operation Set -> Auto Relock ¹
5.011 s Auto relock time.
Door Lock Operation Set (RF Unlock) ->
Door Lock Operation Set (RF Lock) ¹
5.348 seconds
Manual Unlock via Thumb turn/
One Touch Lock via Keypad/
User Code Unlock/Lock ¹
45 milliseconds
User Code Get
40 milliseconds
User Code Set
(Adding Single User Code) ²
492 milliseconds
User Code Set
(Deleting Single User Code)
640 milliseconds
User Code Set
(Deleting All User Codes)
1.724 seconds
Configuration Get
(Single Parameter) ³
40 milliseconds
Configuration Set
(Single Parameter) ³, ⁴
40 milliseconds
Battery Get
40 milliseconds
¹ Our Motor operating time for moving deadbolts is 2 seconds.
² When multiple user codes are added in the Yale locks, an additional registration time of 230
milliseconds needs to be accounted for from User Code Set of Slot 1 to User Code Set of Lock’s last
slot.
³ During initial Configuration Get or Set commands the overall timing for completion of these
commands increases due to the module requesting all values of each parameter the lock supports. If
lock supports 12 parameters, the total time the initial Configuration Get or Set command will take is
1.430 seconds.
⁴ When Configuration Parameter 8, Operation Mode feature, is set to value 3, Passage Mode, this also
results in disabling the following configuration parameters 2 (Auto Relock feature). Therefore, Total
Time will be 260 milliseconds. When Configuration Parameter 16, Escape Return Mode feature, is
enabled, this also results in disabling the following configuration parameters 2 (Auto Relock feature)
and 11 (One Touch Locking feature). Therefore, Total Time will be 390 milliseconds.