background image

An ASSA ABLOY Group brand

80-9150-8005-010 (10-12)

7

Battery Replacement

 

Troubleshooting

 

 

P r  o

  b

   l em

Green light comes on but lever will not retract latchbolt.   

 

 

Solution 

Check lockbody connection.  Check cylinder tail piece length (see Installation Instructions).  

    

Problem 

No Lights come on when pushbuttons are depressed. 

Solution 

 

Problem 

No Audible when pushbuttons are depressed. 

Solution 

 

Problem 

Factory default codes not working 

Solution 

Reprogram default codes (Delete All Users) (See page 5) .      

 

Problem 

User codes not working  

Solution 

 

Problem 

Lock stays unlocked 

Solution 

 
 
 

 

The lock goes into Blackout Mode when the voltage drops to 5.4V. If this happens users 6-99
will be locked out. Supervisor and Emergency codes are the only codes that will allow access.

The codes will not be lost during battery replacement or low power conditions. Codes are stored
in non-volatile memory. To replace the batteries remove the screw on the Battery Escutcheon 
and remove the escutcheon. Replace all 6 “AA” (alkaline only) batteries in the correct polarity 
position. Reinstall the escutcheon. Enter a known user code to ensure lock functions correctly. 

Ensure Visual Keypad Feedback is set to Enable (See page 6). Check battery installation. 
Check keypad connection.

Ensure Audible Keypad Feedback is set to Enable (See page 6). Check battery installation. 
Check keypad connection.

Ensure Lockout code has not been entered (See page 3). Check battery power (lock maybe in 
Blackout Mode). See below for battery replacement. Check lockbody connection.  

 

 Ensure Passage code has not been entered (See page 3). Check cylinder tail piece length 
(see Installation Instructions). Check lockbody connection.  

 

Check door Prep (refer to door templates).

Summary of Contents for E8850FL MortiseSeries

Page 1: ...ational Modes Secure Normal locked state Any assigned user code can gain access Lock relocks automatically Lockout Lockset will not accept any assigned user codes except for the Supervisor and Emergen...

Page 2: ...ous master code stays valid 3 During programming mode the yellow LED will flash continuously at normal rate To enter the lock into programming mode the key is held depressed for 3 seconds The yellow L...

Page 3: ...user to delete the emergency passage lock out codes Note if Code 61 is utilized for this purpose the functions will be completely non operational no code assigned at this point closet door User 4 Loc...

Page 4: ...default to 3131 Hold pound depressed until Yellow LED blinks continuously Enter current Master Code 1234 Yellow LED Blinks Enter Program Command Code PCC 51 Yellow LED Blinks Enter User Number 1 Yello...

Page 5: ...GRAM GUIDE User Programming Commands General Format MC PCC User LOC VAL 1 VAL 2 To Enter a Master Code MC 51 1 4 7 Digits 4 7 Digits To Enter a Emergency Code MC 51 2 4 7 Digits 4 7 Digits To Enter a...

Page 6: ...Mode 4 short beeps followed by 4 long tones will sound but the lock will not open The lock will function for the Supervisor and Emergency Codes only See page 7 for the battery replacement 3 Request T...

Page 7: ...cess The codes will not be lost during battery replacement or low power conditions Codes are stored in non volatile memory To replace the batteries remove the screw on the Battery Escutcheon and remov...

Page 8: ...0 10 12 8 eBOSS User Log Door Description Installation Date User User Name PIN Number Notes 1 Master Code 2 Emergency Code 3 Supervisor 4 Lockout 5 Passage 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21...

Page 9: ...An ASSA ABLOY Group brand 80 9150 8005 010 10 12 9 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77...

Page 10: ...materials are protected under U S copyright laws All contents current at time of publication Yale Security Inc reserves the right to change availability of any item in this catalog its design construc...

Reviews: