Operational Check (Lock must be properly installed, refer to Installation Instructions)

Insert key into outside cylinder and rotate key  
The key will retract the latchbolt 
Inside lever retracts latchbolt 
Enter factory set Emergency code 4321 

*

 

]

 to unlock the outside lever and retract the 

latchbolt (If emergency code does not work refer to Programming Instructions and reprogram 
lock with a new master code and emergency code).  The unit will relock after 10 seconds 
If lock is functioning properly go to Programming Instructions. 
If the lock does not function properly refer to troubleshooting page 7. 

 

Lock Operation: 

Programming is performed through a 12 digit keypad that has the numbers 0-9, 

*

 

]

 and [ # ] keys.  

The [ # ] acts as the entrance into programming mode (press & hold for 3 seconds). The [ # ] key also 

acts  as  a  enter  key  during  programming  and  is  used  after  each  code  entry.  If  the 

]

  key is 

reentered within 5 seconds after programming a code, the unit re-enters the programming mode 

and looks for the next program code. The 

*

 

]

 Key acts a finish key after every user code entry 

In normal operating mode. 

 

Note: 

1)  No programming can be made until the master & emergency codes are changed from the 

factory presets. Once the factory preset master or emergency codes are changed they can   

 2)  When changing the master code, if the new master code verification does not match, then the 

lock exits programming mode and the previous master code stays valid. 

 3)  During programming mode, the yellow LED will flash continuously at normal rate.  To enter 

the lock into programming mode, the [ # ] key is held depressed for 3 seconds. The yellow 
LED will begin flashing and the [ # ] key can be released.  During each entry of the program 
codes, the yellow LED will continue flashing.  At the end of the last program value, the green 
LED will short flash twice and the horn will emit 2 short tones to indicate that valid values 

were entered.  Pressing the 

*

 

]

  key at any time during programming will exit the program 

sequence and a long red flash and 1 very long tone will result.  

  

If a program value is entered out of range, the long red LED will light and a very long tone will 
sound indicating an invalid entry.  Programming mode can be reinitiated within 5 seconds of 
the error by depressing the [ # ] key otherwise programming mode is exited.  

 

4)  After programming mode is exited, the lock always defaults to the standard user mode. 

(Passage & Lockout are automatically exited) 

 

5)  Upon depression of each key, the yellow LED, if enabled (PCC=32), will light for 50 msec.  

The sounder, if enabled (PCC=31) will sound one short tone. 

 6)  Upon 3 (default) successive invalid faceplate entries (PCC=33), the lock will light one long 

red flash along with a long tone and the faceplate will inhibit further entries for a 
Preprogrammed (10 sec default) time (PCC=34).  

During this inhibit time the sounder will 

produce 

 

 

Abbreviations Table

 

 

 

MC 

Master Code 

PCC 

Program Command Code 

VAL 

Value 

Enter Key 

*

 

Finish Key 

def 

Default 

dis 

Disable 

EN 

Enable 

LOC 

User Location 1 through 99 

#

not be reprogrammed back into the unit.

one short tone per second.    

Summary of Contents for eBOSS E5400LN Series

Page 1: ...ational Modes Secure Normal locked state Any assigned user code can gain access Lock relocks automatically Lockout Lockset will not accept any assigned user codes except for the Supervisor and Emergen...

Page 2: ...ous master code stays valid 3 During programming mode the yellow LED will flash continuously at normal rate To enter the lock into programming mode the key is held depressed for 3 seconds The yellow L...

Page 3: ...user to delete the emergency passage lock out codes Note if Code 61 is utilized for this purpose the functions will be completely non operational no code assigned at this point closet door User 4 Loc...

Page 4: ...default to 3131 Hold pound depressed until Yellow LED blinks continuously Enter current Master Code 1234 Yellow LED Blinks Enter Program Command Code PCC 51 Yellow LED Blinks Enter User Number 1 Yello...

Page 5: ...GRAM GUIDE User Programming Commands General Format MC PCC User LOC VAL 1 VAL 2 To Enter a Master Code MC 51 1 4 7 Digits 4 7 Digits To Enter a Emergency Code MC 51 2 4 7 Digits 4 7 Digits To Enter a...

Page 6: ...Mode 4 short beeps followed by 4 long tones will sound but the lock will not open The lock will function for the Supervisor and Emergency Codes only See page 7 for the battery replacement 3 Request T...

Page 7: ...cess The codes will not be lost during battery replacement or low power conditions Codes are stored in non volatile memory To replace the batteries remove the screw on the Battery Escutcheon and remov...

Page 8: ...0 10 12 8 eBOSS User Log Door Description Installation Date User User Name PIN Number Notes 1 Master Code 2 Emergency Code 3 Supervisor 4 Lockout 5 Passage 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21...

Page 9: ...An ASSA ABLOY Group brand 80 9150 8005 010 10 12 9 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77...

Page 10: ...materials are protected under U S copyright laws All contents current at time of publication Yale Security Inc reserves the right to change availability of any item in this catalog its design construc...

Reviews: