background image

WIRING HARNESS
CONNECTOR FROM
KEYPAD

MOTOR CONNECTOR
FROM LOCKBODY

6 AA Batteries

REMOVE TAB AFTER
INSTALLATION

REMOVE

BEFORE

USE

ELECTRICAL CONNECTIONS

Inside

LH

LHR

Inside

RH

RHR

Note 1:
Caution make sure wires
from Lock Body pass thru
slot in Rose Plate then
thru slot in Escutcheon

Comes Assembled
in Lever Handle

Route Lock Motor

 Wires above

Cover Mtg. Tab

9

Grounding
Strip

See Page 10 for Screw Install

Summary of Contents for eBOSS E5400LN Series

Page 1: ...visor and Emergency Codes Passage Maintains unlocked state Relocks by entering passage code the second time Installation Instructions 80 9150 8004 010 Rev D NOTE TO INSTALLER FAILURE TO FOLLOW THESE I...

Page 2: ...nstallation 4 II A How to Change Hands Standard Cylinder Locks 4 II B How to Change Hands Interchangeable Core Cylinder and Non Cylinder Locks 5 II C Adjust lock for door thickness If necessary 5 II D...

Page 3: ...centerline for the lock on the edge and on both sides of the door at the desired height above the finished floor Standard height for horizontal centerline is 40 5 16 above finished floor See Figure1...

Page 4: ...Lock for Installation Left Hand Reverse Hinges on left opens outward For handed locks specify LHR Left Hand Hinges on left opens inward For handed locks specify LH Right Hand Hinges on right opens in...

Page 5: ...r A Remove 2 screws from outside rose B Slide outside rose away from lock body C Pull pins out of lock body D Adjust rose plate to desired door thickness per illustration below E Slide pins back into...

Page 6: ...inders that are furnished with 5400LN locks Trying to install a standard cylinder in 1 3 4 2 thick doors with a E5496LN lock will DAMAGE the lock body Standard 6 7 pin cylinders may only be used on 2...

Page 7: ...r Bolt Tail Retractor Latch Case Retainer Leg Frame Use Caution not to Damage Wires while placing Wires and Lock Body thru Cutout III A INSTALL MECHANICAL COMPONENTS SECTION III INSTALL LOCKSET CONTIN...

Page 8: ...Ass y with Thru Bolt See Next Page for attaching Wiring Harness III B INSTALL ELECTRONIC COMPONENTS SECTION III INSTALL LOCKSET CONTINUED CONTROLLER BOARD ASSEMBLY 1 DIA HOLE REMOVE BEFORE USE Wire t...

Page 9: ...LLATION REMOVE BEFORE USE ELECTRICAL CONNECTIONS Inside LH LHR Inside RH RHR Note 1 Caution make sure wires from Lock Body pass thru slot in Rose Plate then thru slot in Escutcheon Comes Assembled in...

Page 10: ...to the Rose Escutcheon 2 Check the clearance where the two meet If the clearance is acceptable remove the Battery Escutcheon and proceed to step 4 3 If the clearance is to great loosen the Thru Bolt a...

Page 11: ...or Marker 80 8150 0036 010 2 15 32 62 7 C L Vertical C L Horizontal Grounding Strip can be installed in either position Inside of Door 5 16 2 Holes 8 Thru Door CAUTION Office copiers and facsimile mac...

Page 12: ...ames may be trademarks or registered trademarks of their respective owners and are mentioned for reference purposes only These materials are protected under US copyright laws All contents current at t...

Reviews: