background image

9

Key Pad Modes:

Table 1

Key Fob Modes:

Table 2

• 

Sending learn signal

   Press any key except the Emergency (+) button.

• 

Siren tamper (Enable)

  Press and hold down Arm and Emergency (+)  

buttons together for 5 seconds. 

• 

Siren tamper (Disable)

  Press and hold down Arm and Home buttons 

together for 5 seconds. 

• 

Learn mode (Enter)

  Press and hold down Home and Emergency (+) 

buttons together for 5 seconds. 

• 

Learn mode (Exit)

  Press and hold down Disarm for 5 seconds. 

Entering setting mode:

Press Panic Button A followed by your PIN Code   

(factory default is 0000)

.

(The LED on the keypad will start flashing. You can now 
select the desired mode/function)

Function setting:

Press Panic Button A , followed by one of the 
following number keys:

1.

  Send learning/testing signal (same as 8+9)

2.

  Disable Siren tamper

3.

  Enable Siren tamper

4.

  Enter learn mode 

(not suitable for first time set-up)

5.

  Exit learn mode

7.

  Key Pad to work with Control Panel or Smart  

     Hub based sysem.

8.

 Key Pad to work with Siren based system  

    (e.g. EF-KIT1 and EF-KIT4)

Exiting setting mode:

Press Disarm twice. 

(The LED will now stop flashing. If not, press Disarm twice 
again)

Using your Panic Button

Activate an Alarm

•  Press and hold the red button for at least 3 

seconds. The LED will light momentarily and the 
alarm will be activated.

Silence an Alarm

1.

  Press and hold down the red button for 10 

seconds. The LED will light momentarily for a 
second time and the alarm will be silenced.

2.

  Please note that silencing the alarm with the Panic 

Button does not reset the system. If the alarm is 
armed prior to activation, the system will re-arm 
after being silenced with the Panic Button.

3.

  The system will require a reset at the Smart Hub 

after being silenced with the Panic Button.

Using your Smoke Detector

Smoke Detection

When smoke is detected the device will activate for a
minimum of 10 seconds with a two tone alarm and
flashing LED. The Detector will send a radio signal to
the Smart Hub. You will then be notified via a push
notification, SMS and email .
•  Pressing the test button when in an alarm condition
will silence the alarm for 10 minutes. It will
automatically resume smoke detection again after
this period.

Testing

•  Smoke Detector testing should be done on a 

regular monthly basis. Pressing the test button will 
make the LED flash, the audible sounder chime 
and will send a radio test signal to the Smart Hub 
when the button is released. If nothing happens 
after pressing the test button, it indicates the 
batteries will need changing.

Recalibration

•  The Smoke Detector might need recalibrating after 

time to ensure it is working at its optimum. This is 
done by pressing and holding the test button until 
the LED flashes and beeps after 10 seconds. The 
Detector will then start its self calibration routine.

Using your Key Pad

•  The Key Pad can be used to Away Arm and Home 

Arm the system using the buttons as shown.

•  The system is disarmed by pressing the disarm button 

followed by your PIN code.

•  An emergency alarm can be activated by pressing 

the panic A and B buttons simultaneously. Deactivate 
panic event by pressing the disarm button followed by 
your PIN code.

•  If there is a system fault, you will need to press the 

Arm/Home Arm button for a second time to “force 
arm” the system.

Summary of Contents for EF-KIT1

Page 1: ...he correct tools are used Wear goggles or protective clothing where required The Siren is extremely loud please ensure you replace the cover and retreat to a safe distance before testing Special Notes on Compatibility This alarm system is NOT compatible with HSA6000 series and HSA3000 series accessories Please note the prefix EF on the front of the part number to indicate compatibility Note Not co...

Page 2: ...xtend the system Extend the system in the future to increase your security or as your needs change For example add extra PIR Motion Detectors in bedrooms and extra Door Window Contacts 30 devices in total including Key Pad Yale R ale Y Door Window Contact Use one Door Window Contact on a door that is used as the main point of entry and exit usually your front door The other Door Window Contact can...

Page 3: ...e Y 1 2 3 6 5 4 7 8 9 0 Panic button A Panic button B Disarm HomeArm LED Learn button Press 8 and 9 together Pull out the plastic battery saver tab at the back of the Key Pad This will activate the batteries Button not in use Tamper Switch Learn Button Power Switch Programming Dip Switch Indoor Siren EF KIT4 ONLY Siren Setup 1 Remove the cover by unscrewing the single screw located on the lid 2 En...

Page 4: ...s as shown Keyfob remote control accessory Slide off the battery cover insert the 23A MN21 battery as shown and replace battery cover Switch to on Help button accessory Remove the cover by loosening the fixing screw and insert the 12V battery supplied as shown Please ensure you observe battery polarity Tamper switch per ch xtension terminals Learn Test button Learn Test button On Off switch Key Fo...

Page 5: ...sories please press the learn button on the accessories when the power switch is first turned on and in learn mode to learn each one into the system Do not press the Siren learn button See Chapter 2 for learn button location The Siren will beep each time it receives a learn signal to indicate that the accessory is now recognised by the system i This system is equipped with the latest type of radio...

Page 6: ... base where the plastic is thinner The center two knockout holes are for flat wall mounting while the 4 side holes are for corner mounting Wall fixing knockouts x2 Corner fixing knockouts x4 Battery tab 2 Drill holes into the wall using the knockout holes on the base as a template 3 Fit wall plugs and secure the PIR base with the screws provided 4 Fit the PIR back together and tighten the bottom s...

Page 7: ...hinner 2 Using the holes as a template drill holes in the surface and insert wall plugs if fixing into plaster or brick Screw the rear case to the wall Replace the cover and tighten the screw Mounting the Smoke Detector 1 The base has two mounting slots Using the slots as a template drill holes and insert the wall plugs if fixing to plaster Screw the rear case to the ceiling using the screws provi...

Page 8: ...ored except for the tamper switches The system can be armed when inside the protected area of your premises Key Fob will arm the system instantly without a 20 second exit delay Any detector activated afterwards will trigger an instant alarm The system should be armed when outside the protected area of your premises i Key Pad If the system has been armed with a Key Pad there will be a 20 second ent...

Page 9: ...rm is armed prior to activation the system will re arm after being silenced with the Panic Button 3 The system will require a reset at the Smart Hub after being silenced with the Panic Button Using your Smoke Detector Smoke Detection When smoke is detected the device will activate for a minimum of 10 seconds with a two tone alarm and flashing LED The Detector will send a radio signal to the Smart ...

Page 10: ...Arm and Emergency buttons together continuously for 5 seconds until the LED stops flashing to rearm tamper protection Adding devices to an already installed system The installed system will be controlled by either a Key Fob s or a Key Pad s Using your existing Key Pad 1 Enter Setting mode Press Panic Button A followed by the PIN Code Indicated by a continuously flashing LED 2 Switch OFF system tam...

Page 11: ...spring is fully depressed when re fitting the PIR to the back case If this has not been done correctly this will be indicated by a flashing LED on the PIR Siren Battery Change When the batteries start getting low the Siren will produce a series of audible pips and flashes during arming and disarming 1 Switch off tamper protection as described on page 9 Table 1 2 Remove the Siren lid and switch the...

Page 12: ...w the Key Pad case back on and the battery change is complete Panic Button Battery Change When the battery is low the LED will glow dimly when the button is pressed The battery is changed as follows 1 Loosen the bottom case screw and take button cover off base 2 Insert the new CR2032 coin cell battery with the side uppermost see picture below 3 Replace button cover Press the button and check that ...

Page 13: ...ery compartment and ensure the battery pin stays above the battery The Siren will not respond to the disarm PIN code Ensure that the Key Pad mode is correct by entering test mode and pressing Panic Button A then 8 Forgotten user PIN code See Key Pad reset procedure on page 14 PIR Motion Detector PIR does not respond to motion Previous motion has triggered the PIR sleep timer and is preventing subs...

Page 14: ...learn button on device to learnt in Key Pad reset procedure The Key Pad is tamper protected Please ensure the siren tamper is disabled before you open the Key Pad cover See Page 9 table 1 for siren tamper disable procedure Open cover and remove battery Reinsert with the number 3 key pressed taking care 3 is held down The Key Pad will go back to the 0000 Key Pad code The Key Pad will now have to be...

Page 15: ... 6V 4 x D alkaline batteries PIR Motion Detector Alarm processing Microprocessor controlled dual edge sequential pulse count with pulse length discrimination Radio 868MHz FM Power supply 4 5V 3 x AAA alkaline batteries Movement detection range 12 metres 110 Door Window Contact Radio 868MHz FM Power supply 3V CR2032 lithium coin cell battery Smoke Detector Radio 868MHz FM Power supply 4 5V 3 x AA a...

Page 16: ...nd WV13 3PW Declare under our sole responsibility that the following product s Yale Model SR PIR EF PIR SR PETPIR EF PETPIR SR DC EF DC SR KF EF KF SR KP FE KP SR PB EF PB SR SD EF SD SR BX EF BX SR PC EF BXINT SR PVC EF PANEL SR PS EF IPBOX SR RS EF INTBOX SR SR EF Easy Fit Alarm Kits SR EIR SR SR SR WS SR CO SR HUB SR HUL SR HSL SR MZ8 SR Smart Home Alarm kits SR Standard Alarm kits SR Smartphon...

Reviews: