9
Key Pad Modes:
Table 1
Key Fob Modes:
Table 2
•
Sending learn signal
Press any key except the Emergency (+) button.
•
Siren tamper (Enable)
Press and hold down Arm and Emergency (+)
buttons together for 5 seconds.
•
Siren tamper (Disable)
Press and hold down Arm and Home buttons
together for 5 seconds.
•
Learn mode (Enter)
Press and hold down Home and Emergency (+)
buttons together for 5 seconds.
•
Learn mode (Exit)
Press and hold down Disarm for 5 seconds.
Entering setting mode:
Press Panic Button A followed by your PIN Code
(factory default is 0000)
.
(The LED on the keypad will start flashing. You can now
select the desired mode/function)
Function setting:
Press Panic Button A , followed by one of the
following number keys:
1.
Send learning/testing signal (same as 8+9)
2.
Disable Siren tamper
3.
Enable Siren tamper
4.
Enter learn mode
(not suitable for first time set-up)
5.
Exit learn mode
7.
Key Pad to work with Control Panel or Smart
Hub based sysem.
8.
Key Pad to work with Siren based system
(e.g. EF-KIT1 and EF-KIT4)
Exiting setting mode:
Press Disarm twice.
(The LED will now stop flashing. If not, press Disarm twice
again)
Using your Panic Button
Activate an Alarm
• Press and hold the red button for at least 3
seconds. The LED will light momentarily and the
alarm will be activated.
Silence an Alarm
1.
Press and hold down the red button for 10
seconds. The LED will light momentarily for a
second time and the alarm will be silenced.
2.
Please note that silencing the alarm with the Panic
Button does not reset the system. If the alarm is
armed prior to activation, the system will re-arm
after being silenced with the Panic Button.
3.
The system will require a reset at the Smart Hub
after being silenced with the Panic Button.
Using your Smoke Detector
Smoke Detection
When smoke is detected the device will activate for a
minimum of 10 seconds with a two tone alarm and
flashing LED. The Detector will send a radio signal to
the Smart Hub. You will then be notified via a push
notification, SMS and email .
• Pressing the test button when in an alarm condition
will silence the alarm for 10 minutes. It will
automatically resume smoke detection again after
this period.
Testing
• Smoke Detector testing should be done on a
regular monthly basis. Pressing the test button will
make the LED flash, the audible sounder chime
and will send a radio test signal to the Smart Hub
when the button is released. If nothing happens
after pressing the test button, it indicates the
batteries will need changing.
Recalibration
• The Smoke Detector might need recalibrating after
time to ensure it is working at its optimum. This is
done by pressing and holding the test button until
the LED flashes and beeps after 10 seconds. The
Detector will then start its self calibration routine.
Using your Key Pad
• The Key Pad can be used to Away Arm and Home
Arm the system using the buttons as shown.
• The system is disarmed by pressing the disarm button
followed by your PIN code.
• An emergency alarm can be activated by pressing
the panic A and B buttons simultaneously. Deactivate
panic event by pressing the disarm button followed by
your PIN code.
• If there is a system fault, you will need to press the
Arm/Home Arm button for a second time to “force
arm” the system.