CAUSE B - ENCODER FAULT
PROCEDURE OR ACTION:
NOTE:
Connect battery.
NOTE:
Operate traction motor while performing this test. Voltage output will alternate between 5 Vdc and 0 Vdc
as motor rotates.
1. Disconnect the Combination controller connector CPS01 and measure voltage between socket 13, 14, and
B(-).
Does voltage signal relate to traction motor movement?
YES:
Proceed to CAUSE C.
NO:
Replace faulty encoder.
CAUSE C - FAULTY TRACTION CONTROLLER
PROCEDURE OR ACTION:
1. If no faults are found, replace controller. Make sure to indicate the DTC code(s) on the warranty claim to
include an accurate problem description leading to controller replacement.
END POSSIBLE CAUSES