DTC 30067
MainCont (Stuck Closed)
POSSIBLE CAUSE
A. MAIN CONTACTOR COIL WIRING FAULT
B. MAIN CONTACTOR STUCK CLOSED
C. FAULTY TRACTION CONTROLLER
NOTE
Please refer to the end of this procedure for supporting diagrams.
COMPONENT OPERATIONAL CHECK
PROCEDURE OR ACTION:
1. Conduct a visual inspection of all connectors/wiring associated with the fault code.
Are any faults detected/observed?
YES:
Repair/replace connector or wiring associated with faults found. Refer to the appropriate
Electrical
System
YRM.
NO:
Proceed to Step 2.
2. Re-key the vehicle.
Is the code still present?
YES:
Proceed to CAUSE A.
NO:
Problem may be intermittent.
CAUSE A - MAIN CONTACTOR COIL WIRING FAULT
PROCEDURE OR ACTION:
NOTE:
Key in ON position.
1. Disconnect the main contactor coil's positive socket terminal TS07 and measure voltage between the terminal
and B(-).
Is voltage 24 ± 2.5 Vdc?
YES:
Disconnect battery and proceed to Step 2.
NO:
Inspect circuit 239 for open or short.
2. Disconnect the traction controller connector CPS01 and the contactor coil negative terminal TS08. Measure
continuity between TS08 and socket 6 of the traction controller CPS01.
Is continuity present?
YES:
Reconnect battery and all connectors. Proceed to CAUSE B.
NO:
Inspect ground control circuit 075 for open or short.
CAUSE B - MAIN CONTACTOR STUCK CLOSED
PROCEDURE OR ACTION:
NOTE:
Key in OFF position.
1. Measure voltage between controller B(+) and controller B(-).
Is voltage 24 ± 2.5 Vdc?
YES:
Replace faulty main contactor.
NO:
Proceed to CAUSE C.
ELECTRICAL SYSTEM
Diagnostic Trouble Codes
Check the Service Manual section in Yale Axcess Online for possible updates and check pertinent Bulletins
Confidential/Proprietary - Do Not Copy or Duplicate
9030-20-21
Summary of Contents for MPB045VG
Page 1: ...Maintenance CONTROLLER DIAGNOSTICS MPB045VG A245 PART NO 550095689 9000 YRM 1671 ...
Page 4: ......
Page 6: ......
Page 10: ...9030 4 ...
Page 24: ...NOTES 9030 03 14 ...
Page 83: ......
Page 84: ...9000 YRM 1671 10 19 9 15 1 15 12 14 10 14 4 14 ...