Speed Steering Reduction
This optional parameter defines the speed reduction
that the motor will target from its current level once the
speed reduction sensor changes from ON to OFF. If
parameter is set at 75%, and the truck was been
driven at 1000 RPM, upon steering the motor will
decelerate to 750 RPM.
Traction Steering Decel Ramp
This optional parameter will determine the time that it
will take the motor to decelerate from current speed to
speed determined by Speed Steering Reduction
parameter. Larger values represent slower response.
Response-Full Accel Rate HS
This parameter will set the rate (in seconds) at which
the speed command increases when full throttle is
applied at high vehicle speeds. Larger values
represent slower response. See Figure 9030-03-2 for
relationship between Full Accel Rate HS, Full Accel
Rate LS, and Low Accel Rate.
NOTE:
IN THIS EXAMPLE, HS = 70%, LS = 30%, TYPICAL MAX SPEED = 5000 RPM
Figure 9030-03-2. Acceleration Response Rate Diagram
Response-Full Accel Rate LS
This parameter sets the rate (in seconds) at which the
speed command increases when full throttle is applied
at low vehicle speeds.
Response-Low Accel Rate
This parameter sets the rate (in seconds) at which the
speed command increases when a small amount of
throttle is applied. This rate is typically adjusted to
affect low speed maneuverability.
Response-Neutral Decel Rate HS
This parameter sets the rate (in seconds) that is used
to slow down the vehicle when the throttle is released
to neutral at high vehicle speeds.
Response-Neutral Decel Rate LS
This parameter sets the rate (in seconds) that is used
to slow down the vehicle when the throttle is released
to neutral at slow vehicle speeds.
Fine Tuning-Partial Decel Rate
This parameter sets the rate (in seconds) that is used
to slow down the vehicle when the throttle is reduced
without being released to neutral. Larger values
represent slower response.
Fine Tuning-HS (High Speed)
This parameter sets the percentage of the Typical Max
Speed above which the “HS” parameters will be used.
General Maintenance and Diagnostic Data
ELECTRICAL SYSTEM
Check the Service Manual section in Yale Axcess Online for possible updates and check pertinent Bulletins
9030-03-8
Confidential/Proprietary - Do Not Copy or Duplicate
Summary of Contents for MPB045VG
Page 1: ...Maintenance CONTROLLER DIAGNOSTICS MPB045VG A245 PART NO 550095689 9000 YRM 1671 ...
Page 4: ......
Page 6: ......
Page 10: ...9030 4 ...
Page 24: ...NOTES 9030 03 14 ...
Page 83: ......
Page 84: ...9000 YRM 1671 10 19 9 15 1 15 12 14 10 14 4 14 ...