background image

Top Jamb Installation Using 587 Dropplate

Page 3

7

(178)

1/2

(13)

7/8

(22)

5

(127)

1-3/4

(44.5)

1-3/4

(44.5)

C

L

A

Installation Sequence

!

!

!

!

!

!

!

!

!

Select door opening angle using template above. Mark 4 holes on

frame face for Dropplate and 2 holes on door for arm shoe.

Prepare door and frame for fasteners. See “Preparation for

Fasteners” at bottom of Page 2.

Mount drop plate to frame.

Install closer to drop plate with “S” and “L” adjustment valves

toward hinge edge of door.

Mount arm shoe to door.

Install main arm onto closer pinion shaft, indexing main arm mark

“S” with pinion flat as shown at right. Fasten with arm screw.

Screw pinion cap onto pinion shaft by hand or with a Phillips

screw driver - DO NOT OVER TIGHTEN.

Adjust closer.

!

251 or 251BF Models Only. Set closing power using “Power

Adjustment Chart” at bottom of Page 2.

Open door to allow connecting rod to be inserted into arm slide.

Insert rod and  close door. Preload main arm by rotating away
from hinge until forearm is perpendicular (at 90° angle) to door.
Secure with forearm screw.

Door Closer Adjustment (Continued)

“DA” suffix (Delayed Action) is an optional feature.
A separate instruction will be packed with these instructions showing valve locations and adjustment procedures.

Closing Speed Control

CAUTION:

DO NOT BACK VALVES OUT OF

CLOSER OR A LEAK WILL

RESULT

Attention: Adjust Closing Speed
Time to between 4 to 7 seconds
from 90°. Use of the door by
handicapped, elderly or small
children may require greater
closing time.

Standard Closing Cycle

CLOSED

SWEEP

L

A

T

C

H

10°

Unit Adjustment

Closing Speed Controls (Figure 1)

!

!

Valve “S” controls sweep range.
Valve “L” controls latch range.

Opening Door Control

Opening Cycle

O

P

E

N

IN

G

Opening Door Control

!

Backcheck (”BC”) valve controls the hydraulic resistance to door
opening in backcheck range. NEVER close this valve completely
– it is not to provide a positive stop.

BACKCHECK

Template

Hinge or Pivot

Side Elevation

Typical Installation

Right Hand Door

Left Hand Door

Figure 2

Figure 1

CAUTION:

DO NOT BACK VALVES OUT OF

CLOSER OR A LEAK WILL

RESULT

• Do not scale drawing.
• Left hand door shown.
• Dimensions are in inches (mm).

Opening

To 100°

101° to 120°
121° to 180°

Dimension A

inches

8-1/2

7

4-1/2

mm
216

177.8

114

* Door/Wall/Hardware/Jamb

conditions permitting

Optional

“BC”

Valve

“S” & “L”

Valves

Power

Adjustment

Screw

Preload

Preload

Pinion Flat

“S” & “L”

Valves

1

2

3

4

Z

Y

S

Pinion Flat

1

2

3

4

Z

Y

S

4

(101.6)

1-1/2

(38.1)

Summary of Contents for Narrow Profile Series

Page 1: ...these instructions Use this instruction sheet for installation sequence and closer adjustments only It is recommended that the door on which the door closer will be installed be hung on ball bearing hinges Door must swing freely A separate door stop supplied by others is recommended to prevent damage to the door closer closer arm or to the door frame or adjacent walls Door and Frame must be proper...

Page 2: ...main arm by rotating away from hinge until forearm is perpendicular at 90 angle to door Secure with forearm screw Screw pinion cap onto pinion shaft by hand or with a Phillips screw driver DO NOT OVER TIGHTEN Adjust closer Door Closer Adjustment Power Adjustment Chart DOOR INTERIOR INTERIOR EXTERIOR EXTERIOR 251BF 251 TYPE OF INSTALLATION REGULAR ARM TOP JAMB PARALLEL ARM REGULAR ARM TOP JAMB PARA...

Page 3: ...eature A separate instruction will be packed with these instructions showing valve locations and adjustment procedures Closing Speed Control CAUTION DO NOT BACK VALVES OUT OF CLOSER OR A LEAK WILL RESULT Attention Adjust Closing Speed Time to between 4 to 7 seconds from 90 Use of the door by handicapped elderly or small children may require greater closing time Standard Closing Cycle CLOSED SWEEP ...

Page 4: ...r with a Phillips screw driver DO NOT OVER TIGHTEN 251 or 251BF Models Only Set closing power using Power Adjustment Chart at bottom of Page 2 Mount 214 dropplate only if required Adjust closer See Closer Adjustments on Pages 2 and 3 Side Elevation To 100 101 to 130 Over 131 9 1 4 7 3 4 5 3 4 235 197 146 7 5 8 6 1 8 4 1 8 194 156 105 8 5 8 7 1 8 5 1 8 219 181 130 Door Opening Dimension A Dimension...

Reviews: