background image

Parallel Arm Installation

Page 4

2-3/4

(69.9)

3/8

(9.5)

5/16

(8)

7/16

(11.1)

2

(50.8)

1-1/2

(38.1)

7

(177.8)

4

(101.6)

1-1/8

(29)

2-1/4

(57)

1/2

(12.7)

3/4

(19.1)

9-1/16

(230.2)

C

L

A

C

B

1-1/2

(38mm)

Template

Holes for 214 Plate only

Installation Sequence

!

!

!

!

!

!

!

!

Select door opening angle using template above. Mark 4 holes
on door for closer or 214 dropplate and 4 holes on frame for
soffit plate.

Install closer with “S” and “L” adjustment valves toward lock
edge of door.

Mount soffit plate to frame.

Install main arm onto closer pinion shaft. Rotate pinion 45°
toward hinge edge of door to align main arm letter “3” (right
hand) or “2” (left hand) with pinion flat. Fasten with arm screw.

Fasten forearm to soffit plate. Adjust forearm length to set arm
elbow about 1-1/2” (38mm) from door when connected to main
arm. Tighten forearm screw.

Prepare door and frame for fasteners. See “Preparation for
Fasteners” bottom of Page 2.

Screw pinion cap onto pinion shaft by hand or with a Phillips
screw driver - DO NOT OVER TIGHTEN.

251 or 251BF Models Only. Set closing power using “Power
Adjustment Chart” at bottom of Page 2.

Mount 214 dropplate ... only if required.

!

!

Adjust closer. See Closer Adjustments on Pages 2 and 3.

Side Elevation

To 100°

101° to 130°

Over 131°

9-1/4

7-3/4

5-3/4

235

197

146

7-5/8

6-1/8

4-1/8

194

156

105

8-5/8

7-1/8

5-1/8

219

181

130

Door

Opening

Dimension A

Dimension B

Dimension C

Inches

Inches

Inches

mm

mm

mm

Hinge or
Pivot

• Do not scale drawing
• Left Hand shown
• Dimensions are in inches (mm)

Typical Installation

Left Hand Door

Optional

“BC”

Valve

S & L

Valves

Power

Adjustment

Screw

Pinion Flat

Optional

“BC”

Valve

Power

Adjustment

Screw

Right Hand Door

1

2

3

4 Z

Y

S

Pinion Flat

1 2

3

4

Z

Y

S

An ASSA ABLOY Group brand

3000 Highway 74 East  •  Monroe, NC 28112
Tel: (800)-438-1951  •  Fax: (800)-338-0965

www.yalecommercial.com

Yale ® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company.
Copyright © 2001, 2009, Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.

Summary of Contents for Narrow Profile Series

Page 1: ...these instructions Use this instruction sheet for installation sequence and closer adjustments only It is recommended that the door on which the door closer will be installed be hung on ball bearing hinges Door must swing freely A separate door stop supplied by others is recommended to prevent damage to the door closer closer arm or to the door frame or adjacent walls Door and Frame must be proper...

Page 2: ...main arm by rotating away from hinge until forearm is perpendicular at 90 angle to door Secure with forearm screw Screw pinion cap onto pinion shaft by hand or with a Phillips screw driver DO NOT OVER TIGHTEN Adjust closer Door Closer Adjustment Power Adjustment Chart DOOR INTERIOR INTERIOR EXTERIOR EXTERIOR 251BF 251 TYPE OF INSTALLATION REGULAR ARM TOP JAMB PARALLEL ARM REGULAR ARM TOP JAMB PARA...

Page 3: ...eature A separate instruction will be packed with these instructions showing valve locations and adjustment procedures Closing Speed Control CAUTION DO NOT BACK VALVES OUT OF CLOSER OR A LEAK WILL RESULT Attention Adjust Closing Speed Time to between 4 to 7 seconds from 90 Use of the door by handicapped elderly or small children may require greater closing time Standard Closing Cycle CLOSED SWEEP ...

Page 4: ...r with a Phillips screw driver DO NOT OVER TIGHTEN 251 or 251BF Models Only Set closing power using Power Adjustment Chart at bottom of Page 2 Mount 214 dropplate only if required Adjust closer See Closer Adjustments on Pages 2 and 3 Side Elevation To 100 101 to 130 Over 131 9 1 4 7 3 4 5 3 4 235 197 146 7 5 8 6 1 8 4 1 8 194 156 105 8 5 8 7 1 8 5 1 8 219 181 130 Door Opening Dimension A Dimension...

Reviews: