background image

20

P/N 80-9150-0080-010 (10-17)

Definitions

All Code Lockout Mode:

This feature is enabled by the Master code. When enabled, it restricts all user (except

Master)

code access. When attempting to enter a code while the unit is in Lockout, the

locked padlock

PIN

RED

will appear on the screen. (Main Menu selection #6.)

Automatic Re-lock Time:

After a successful unlock, the unit will re-lock automatically after 5 seconds or for a

duration selected in the

(Main Menu selection #3 then #1).

Advanced Lock Settings

Language Setting Mode:

Choose English (1), Spanish (2) or French (3) for the lock's voice prompts. (Main

Menu selection #5.)

Low Battery:

When battery power is low, the Low Battery Warning indicator flashes

. If battery power is

RED

completely lost, use the 9Volt battery override. To use the 9V battery override apply 9V battery, in either
direction, to terminals on the touchscreen for backup power option. Activate the touchscreen and enter your pin
code to unlock the door.

Master

Code:

It must be created

PIN

The Master

code is used for programming and for feature settings.

PIN

prior to programming the lock.

The Master code will also operate (unlock/lock) the lock.

Network Module Setting:

With the optional Network Module installed, this setting becomes available (Main

Menu selection #7) and allows the lock to connect with a network controller.

One Touch Locking:

When the unit is unlocked, activating the touchscreen will lock the unit (during Automatic

Re-lock duration or when Automatic Re-lock is disabled). When One-Touch Re-lock is

in use

any

not

(disabled),

valid

code will re-lock the lock. (Main Menu selection #3 then #3.)

PIN

Privacy Button to Lock Door:

If Automatic Re-lock is disabled, a short 1 second press of this button will lock the

door.

Privacy Mode:

With optional Door Position Switch installed, Privacy Mode enabled thru Menu Mode and door

closed, all keypad functions can be disabled with a 3 second press of the Privacy Button. Privacy Mode is
disabled by default. Enable Privacy Mode thru Main Menu selection #3 then #4. With door closed, press and
hold the privacy button until voice prompt indicates Privacy Mode is enabled. Privacy Mode duration ends when
door is opened and voice prompt indicates Privacy Mode is disabled.

Shut Down Time:

The unit will shut down for sixty (60) seconds and not allow operation after the wrong code

entry limit (5 attempts) has been met. When the unit is in Shut down, the keypad will be flashing.

Tamper Alert:

Audible alarm sounds if attempting to forcibly remove outside lock from door.

User

Code:

PIN

The User code operates the lock. Maximum number of user codes is 500.

Volume Setting Mode:

(1)

The volume setting for

code verification is set to

by default; otherwise it

PIN

HIGH

can be set to

or

for quiet areas. (Main Menu selection #4.)

Low (2)

Silent (3)

Wrong Code Entry Limit:

After five (5) unsuccessful attempts at entering a valid

code, the unit will shut

PIN

down and not allow operation. When the unit is in Shut Down, the keypad will be flashing.

Summary of Contents for nexTouch

Page 1: ...ay impact fire rating safety features and warranty Consult with code specifications to ensure compliance with all codes and ratings nexTouch Touchscreen and Push Button Access Cylindrical Lock Install...

Page 2: ...nward Left Hand Reverse Hinges Left LHR Open Outward Right Hand Hinges Right RH Open Inward Right Hand Reverse Hinges Right RHR Open Outward The hand of a door is determined from the secure side of th...

Page 3: ...aaaaaaaa aaaaaaaaaaaaaaaaaaaaaaaaaaa aaaaaaaaaaaaaaaaaaaaaaaaaaa aaaaaaaaaaaaaaaaaaaaaaaaaaa aaaaaaaaaaaaaaaaaaaaaaaaaaa SQUARE EDGE DOOR ONLY 5 32 Dia x 1 8 Deep 4mm x 3mm 2 Locations Both sides of d...

Page 4: ...ame 1 Dia x 1 2 Deep Frame DPS Option Wood Frame 3 8 Dia x 1 Metal Frame 3 4 Dia x 1 See Instruction A7983B Inside of Door Frame 3 1 2 7 16 8 32 x 1 UNCWS x2 Metal Frame Installations Supplied plastic...

Page 5: ...5 P N 80 9150 0080 010 10 17 3 Preparing Inside Escutcheon Do not take apart the outside assembly 3 2 1...

Page 6: ...10 10 17 Curved edge of latchbolt faces direction door closes Installing Latchbolt Inside of Door 7 16 8 32 x 1 UNCWS x2 Removing Battery Cover 4 5 2 3 8 Latchbolt for thin doors sold separately See I...

Page 7: ...tside of Door T Tabs Retractor Pocket Mounting Flange Two moving T tabs must be fully captured in retractor pocket Mounting Flanges must be in Mounting Flange Pockets Mounting Flange Pocket Mounting F...

Page 8: ...8 P N 80 9150 0080 010 10 17 7 10 32 x 2 1 2 PFHMS Do Not Overtighten Screws Installing Inside Support Assembly Inside of Door x2 Optional DPS...

Page 9: ...9 P N 80 9150 0080 010 10 17 Attaching Cables Optional DPS Connection Motor Connection Touchpad Connection 8...

Page 10: ...10 P N 80 9150 0080 010 10 17 9 Installing Inside Escutcheon Testing Inside Lever Operation Avoid pinching cables Thin door gaskets sold separately See Installation Options...

Page 11: ...work or Yale Accentra Key module must be installed batteries See BEFORE Installation Options Welcome to Yale Congratulations you ve installed the Yale nexTouch Lock Continue on next page to customize...

Page 12: ...function properly DPS Inside of Door Door Position Switch Option enables Privacy feature Installation Options Outside Gasket Inside Gasket 2 3 8 Latchbolt Adjusting for 1 3 8 Door if necessary Networ...

Page 13: ...before any further programming PIN Max User Codes 500 Lock Activation Interior Escutcheon Privacy Button Speaker Low Battery Indicator Exterior Escutcheon 9Volt Battery Override Terminal Lockout Mode...

Page 14: ...to factory default Programming and use of lock is not possible until this step has been successfully completed Enter 4 8 digit Master Code PIN Press Press Register Master Code Press the gear key to c...

Page 15: ...ster User code Press the gear key to continue Press Press Register User code Press the gear key to continue code registration PIN Enter a 4 8 digit code PIN Press the gear key to continue Menu Mode en...

Page 16: ...ing more User Codes Enter 4 8 digit code PIN Press To end programming Press Registered Press the check key to complete Press the gear key to continue Enter 4 8 digit code PIN followed by Completed Reg...

Page 17: ...17 P N 80 9150 0080 010 10 17 3 Locking Unlocking Door with Registered Master or User Code PIN Enter Code PIN Press...

Page 18: ...18 P N 80 9150 0080 010 10 17 Locking Door with Privacy Button 4 Testing Outside Lever Operation...

Page 19: ...e reset button for 3 seconds 7 While continuing to press the reset button temporarily remove one 1 battery AA 8 Reinstall the battery 9 Release reset button and wait approximately 15 seconds Speaker w...

Page 20: ...the touchscreen will lock the unit during Automatic Re lock duration or when Automatic Re lock is disabled When One Touch Re lock is in use any not disabled valid code will re lock the lock Main Menu...

Page 21: ...g session The Master code must be registered prior to any other programming of the lock PIN Continue Complete Continue Complete 3 U U Privacy Enable Disable Volume Setting Language Setting All Code Lo...

Page 22: ...ccessible Unit is on for a while then shows no reaction Lights dim PIN codes must consist of 4 to 8 digits to register Check or gear cannot be used as part of the code PIN Contact the Master user Chec...

Page 23: ...d verify latchbolt tail is centered between top and bottom of hole b Remove latchbolt and insert lockset Look through latchbolt hole and verify retractor mouth is centered in hole If not adjust outsid...

Page 24: ...interference including interference that may cause undesired operation of the device Le pr sent appareil est conforme aux d Industrie Canada applicables aux appareils radio exempts de licence L explo...

Page 25: ...Inclusion Mode Enter the 4 8 digit Master code followed by the key PIN Press the key followed by the key Press the key followed by the key To Unenroll Remove the Module Exclusion Mode Enter the 4 8 di...

Page 26: ...risque d interf rence aux autres utilisateurs le type d antenne et son gain doivent tre choisies de fa on que la puissance isotrope rayonn e quivalente ne d passe pas ce qui est PIRE n cessaire pour u...

Page 27: ...ated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network To Enroll the Module Inclusion Mode Enter the 4 8 digit Master code followed by the key...

Page 28: ...device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Le pr sent appareil est conforme aux d Industr...

Page 29: ...ove and or insert Network Module Reinstall batteries and battery cover Enrolling the iM1 Network Module The Yale iM1 Network Module must be used with a Yale Assure Lock or Yale nexTouch Lock and canno...

Page 30: ...ompliance with safety and regulatory standards Please note that the use of this accessory with iPod iPhone or iPad may affect wireless performance 1 After following the steps listed on other side of p...