8
Install the range hood into the hood cabinet
1 Determine and make all necessary cuts in the wall or roof for
the vent system. Install the vent system before installing the
cabinet hood insert. See the “Venting Requirements” section.
2 Determine the location where the power supply cable will be
run through the wall.
3
Drill a 1¼” (3.2 cm) hole at this location.
4 Pull enough power supply cable through the wall to allow for
easy connection to the terminal box.
5 Remove terminal box cover and set aside.
6
Install the 10” (25.4 cm) square x 10” (25.4 cm) round vent
transition with damper to top side of the range hood, using 4 -
3.5 x 9.5 mm screws.
7 Remove knockout from the top of the vent hood and install a
UL listed or CSA approved ½” (1.3 cm) strain relief.
8 Place the hood insert near its mounting position and run the
power supply cable through the strain relief into terminal box
(enough to make connection).
9 Tighten the strain relief screws.
10 Using 2 or more people, lift the hood insert into hood cabinet.
11 Fasten the hood insert using four 5 x 45 mm screws to the
hood cabinet and tighten securely.
WARNING
EXCESSIVE WEIGHT HAZARD
USE TWO OR MORE PEOPLE TO MOVE AND INSTALL HOOD
INSERT.
FAILURE TO DO SO CAN RESULT IN BACK OR OTHER
INJURY.
Upper Hood
Insert Motor Housing
4 mounting
screws
Electrical Connection
I
WARNING
ELECTRICAL SHOCK HAZARD.
I
WARNING
DISCONNECT POWER BEFORE SERVICING.
REPLACE ALL PARTS AND PANELS BEFORE OPERATING.
FAILURE TO DO SO CAN RESULT IN DEATH OR
ELECTRICAL SHOCK.
1 Disconnect power.
2 Locate terminal box inside of the hood insert.
A
B
C
D
E
G
F
A.White wires
B. Black wires
C. UL listed wire connectors
D. Green, bare or yellow/green wires
E.Home power supply
F. UL listed or CSA approved ¹⁄
2
” (1.3 cm)
strain relief
G. Ground Wire tab
3
Use UL listed wire connectors and connect black wires (B)
together.
4
Use UL listed wire connectors and connect white wires (A)
together.
I
WARNING
ELECTRICALLY GROUND BLOWER.
CONNECT GROUND WIRE TO GREEN AND YELLOW
GROUND WIRE IN TERMINAL BOX. FAILURE TO DO SO CAN
RESULT IN DEATH OR ELECTRICAL SHOCK.
5
Connect green (or bare) ground wire from home power supply
to the green/yellow ground wire (D) in terminal box using UL
listed wire connectors.
6 Install terminal box cover.
7 Check that all light bulbs are secure in their sockets.
8 Reconnect power.
Complete Installation
1
Install grease filters. See the “Cleaning” section.
2 Check operation of the Hood Insert blower and lights.
See the “Hood Insert Use” section.
3 If the hood insert does not operate, check to see whether a
circuit breaker has tripped or a house hold fuse has blown.
4 Disconnect power supply and check that the wiring is correct.
NOTE: To get the most efficient use from your new hood insert,
read the “Hood Insert Use” section.