Definitions

All Code Lockout Mode:

This feature is enabled by the Master code. When enabled, it restricts all user (except

Master) PIN code access. When attempting to enter a code while the unit is in Lockout, the RED locked padlock
will appear on the screen.

Automatic Re-lock Time:

After a successful code entry and the unit unlocks, it will automatically re-lock after

thirty (30) seconds.

Inside Indicator Light:

Located on the interior escutcheon. Shows active status (Locked) of lock and can be

enabled or disabled in the

(Main Menu selection #3).

Advanced Lock Settings

Language Setting Mode:

Choosing English (1), Spanish (2) or French (3) becomes the (default) setting for the

lock's voice prompts.

Low Battery:

When battery power is low, the Low Battery Warning indicator flashes RED. If battery power is

completely lost, use the cylinder key override.

Master PIN Code:

It must be created

The Master PIN code is used for programming and for feature settings.

prior to programming the lock.

The Master code will also operate (unlock/lock) the lock.

Network Module Setting:

With the optional Network Module installed, this setting becomes available thru the

Main Menu (7) and allows the lock to connect with a network controller.

One Touch Locking:

When the latch is retracted, activating the keypad will extend the latch (during Automatic Re-

lock duration or when Automatic Re-lock is disabled). When One-Touch Re-lock is

in use

any

not

(disabled),

valid PIN code will re-lock the lock.

Previous:

While in Menu Mode, pressing this icon cancels the current operation and returns the user to the

previous step.

Privacy Mode:

Privacy mode is disabled by default. Enable Privacy Mode by pressing the privacy button for 4

seconds to put the lock in do-not-disturb mode (all pin codes are disabled).

Shutdown Time:

The unit will shutdown (flashing RED) for sixty (60) seconds and not allow operation after the

wrong code entry limit (5 attempts) has been met.

Tamper Alert:

Audible alarm sounds if attempting to forcibly remove outside lock from door.

User PIN Code:

The User code operates the lock. Maximum number of user codes is 250 with Network Module;

without Network Module, maximum is 25 user codes. Note: When deleting User PIN code(s), screen will display
User Number (not PIN code) being deleted.

Volume Setting Mode:

Low (2)

The volume setting for PIN code verification is set to

by default; otherwise it can

be set to

or

for quiet areas.

High (1)

Silent (3)

Wrong Code Entry Limit:

After five (5) unsuccessful attempts at entering a valid PIN code,  the unit will shut

down and not allow operation.

Summary of Contents for Real Living Assure Lock YRD226

Page 1: ...allation and Programming Instructions YRD226 x3 8 32 x 5 16 Machine screws x4 7 wood 8 32 machine x 20mm Combination screws x2 M6x59 5mm Long through bolt FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN DAMAGE TO THE PRODUCT AND VOID THE FACTORY WARRANTY Optional Network Module ...

Page 2: ...P N YRL TSINSTL FUL Rev E 2 Preparing Door ...

Page 3: ...P N YRL TSINSTL FUL Rev E 3 Optional Fire Kit Parts For Model YRD620 ONLY Installing Optional Fire Cup Inside of Door O optional O optional ...

Page 4: ... YRL TSINSTL FUL Rev E 4 O x4 1 d faut e 2 3 8 position 2 3 4 position Installing Latch Strike Plate Press Pull optional Bolt must be in retracted unlocked position Note horizontal orientation of mechanism ...

Page 5: ...P N YRL TSINSTL FUL Rev E 5 2 Installing Touchscreen Escutcheon Outside of Door Inside of Door Bolt must be in retracted unlocked position Note horizontal orientation of mechanism O optional ...

Page 6: ...P N YRL TSINSTL FUL Rev E 6 x2 3 Installing Interior Mounting Plate Loosen screw to remove cover O optional ...

Page 7: ...4 Attaching the Cable Assembly P N YRL TSINSTL FUL Rev E 7 ...

Page 8: ...P N YRL TSINSTL FUL Rev E 8 x3 5 Installing Interior Escutcheon ...

Page 9: ...3 Testing Operation Bolt must be in retracted unlocked position before installing batteries P N YRL TSINSTL FUL Rev E 9 ...

Page 10: ...P N YRL TSINSTL FUL Rev E 10 2 Testing Operation ...

Page 11: ...P N YRL TSINSTL FUL Rev E 11 6 Installing Optional Network Module ...

Page 12: ...ling Batteries Cover Congratulations you ve installed the Yale Real Living Assure Lock Touchscreen Deadbolt YRD226 Continue with Programming Instructions to customize your product Tighten screw to replace cover Welcome to Yale Real Living ...

Page 13: ...ated before any further programming Max User Codes 250 with Network Module Max User Codes 25 without Interior Escutcheon Privacy Mode Button Speaker P Key Return to Previous Low Battery Indicator Lockout Mode Exterior Escutcheon P N YRL TSINSTL FUL Rev E 13 ...

Page 14: ...lt Programming and use of lock is not possible until this step has been successfully completed Register Master Code Press the gear key to continue Enter a 4 to 8 digit PIN code followed by the gear key Registered Enter 4 8 digit Master PIN Code Press Press Creating Master PIN Code P N YRL TSINSTL FUL Rev E 14 ...

Page 15: ... Module Max user codes 25 without Menu Mode enter number press the gear key to continue Enter Master PIN code Press Press Press Press Press Press Enter 4 8 digit PIN code Press Enter 4 8 digit PIN code Press code flashes Adding more User Codes To end programming Press P N YRL TSINSTL FUL Rev E 15 ...

Page 16: ...p to 250 Users Master User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ Enter PIN Code Press Code Chart Duplicate if necessary User Name User Type PIN Code Unlocking Door with PIN Code User ...

Page 17: ...t settings see below 1 Remove the battery cover and batteries 2 Remove the interior escutcheon to access the reset button 3 The reset button see image at right is located beside the PCB cable connector 4 While pressing the reset button minimum of 3 seconds reinstall batteries Release reset button 5 Replace battery cover Upon reset Master PIN Code creation is the only option available and must be p...

Page 18: ...gs Factory Setting Master PIN Code Automatic Re lock Disabled Lockout Mode Disabled Language Setting English Wrong Code Entry Limit 5 Times Shutdown Time 60 Seconds Volume Setting Enabled Low Privacy Setting Disabled One Touch Locking Enabled Inside Indicator Light Disabled Off Automatic Re lock Time 30 Seconds Escape Return Mode Model YRD620 only Disabled ...

Page 19: ...ws the lock to connect with a network controller One Touch Locking When the latch is retracted activating the keypad will extend the latch during Automatic Re lock duration or when Automatic Re lock is disabled When One Touch Re lock is in use any not disabled valid PIN code will re lock the lock Previous While in Menu Mode pressing this icon cancels the current operation and returns the user to t...

Page 20: ...efault settings in bold Master PIN Code Setting User PIN Code Registration Continue Complete Register Delete Continue Complete M 2 3 1 Join the Network Enable Disable English Spanish French Silent Low High Complete Exit the Network Volume Setting Language Setting Mode Lockout Mode Network Module Setting Privacy Setting Mode Enable Disable Handing the Lock Preforms automatic handing of the lock Adv...

Page 21: ...U Master PIN Code Setting User PIN Code Registration Continue Complete Register Delete Continue Complete M 2 3 1 Continue Complete Default settings in bold If Escape Return Mode is enabled Automatic Re lock cannot be enabled Language Setting Mode Set Up SEOS Card Advanced Lock Settings Enable Disable English Spanish French Silent Low High Complete Volume Setting Lockout Mode Privacy Setting Mode E...

Page 22: ...ock Mode is enabled Batteries do not have enough power Replace batteries Use mechanical key to gain entry and replace batteries Check to see if touchscreen harness is fully connected and not pinched Check batteries are in good condition replace batteries if discharged If touchscreen numbers are visible check to see if they respond when pressed Touchscreen becomes active when pressed w whole hand U...

Page 23: ...eck for sufficient clearance of the bolt within the strike side jamb Correct this by increasing the depth of the pocket for the bolt b Check for misalignment of bolt and or strike which may be preventing bolt from properly entering the strike With the door open extend and retract the bolt if it is smooth check the strike alignment Bolt does not extend or retract smoothly a Bolt and strike are misa...

Page 24: ...er is connected Consult the dealer or an experienced radio TV technician for help Industry Canada This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Cet appareillage numérique de la classe A répond à toutes les exigences de l interférence canadienne causant des règlements d équipement Warning Yale Security Inc Changes or modifications t...

Reviews: