background image

32

P/N

-

-

-

Rev B

YRL EMICL PBINSTL FUL

Resetting Lock to Factory Default

Factory Setting

Registration

required*

Disabled

Disabled (Off)

Enabled

Disabled

5 Times

60 Seconds

Settings

Master

Code

PIN

Automatic Re-lock

Inside Indicator Light

One Touch Locking

Audio Mode

Wrong Code Entry Limit

Shutdown Time

Disabled

Privacy Button Setting

Disabled

Lockout Mode

Reset Button

Access

Interior Lock

(4" Shown)

Factory Settings

When resetting the lock, all user codes,
including the Master

code*, are deleted. All

PIN

programming features are reset to original
default settings (see below).

1. Remove the battery cover and batteries.
2. Remove the interior lock to access the reset

button hole. (See image at right.)

3. Re-insert 3 batteries and insert a small

screwdriver into the hole; holding the reset
button for 3 seconds.

4. While still holding the reset button, insert the

4th battery and hold the reset button for an
additional 3 seconds.

5. Release the reset button.
6. Re-install the interior lock onto the door.

Upon reset, Master

Code creation is the

PIN

only option available and must be performed
prior to any other programming of the lock.

*The Master

code must be registered prior to any other

PIN

programming of the lock.

For best results, the lock should be installed on the

 

door when resetting the lock to factory default.

 

If the

 

process was done and the lock was not installed on

 

the door, review the Re-Handing instructions listed in

 

Hardware

 

Troubleshooting.

Please use this procedure only when the network 

primary controller is missing or otherwise inoperable

Summary of Contents for Real Living Assure Lock

Page 1: ...tions to ensure compliance with all codes and ratings 4 Touchscreen Shown 5 5 Available Inside of Door Yale Assure Lock Installation and Programming Instructions YRC216 Electronic Interconnected Push Button Network Module Optional Before you begin for step by step installation instructions to register your product DOWNLOAD THE BILT APP Outside of Door ...

Page 2: ...2 P N Rev B YRL EMICL PBINSTL FUL Before You Begin 1 3 8 35mm Min to 1 3 4 44 5mm Max 4 1 2 114 Min x1 x2 x8 Network Module Optional 3 32 1 8 Template x2 x2 x2 2 1 8 2 1 8 1 1 ...

Page 3: ...3 P N Rev B YRL EMICL PBINSTL FUL Mark Door Reference Lines C L REMOVE Template EXISTING 2 3 8 or 2 3 4 Backset ...

Page 4: ...4 P N Rev B YRL EMICL PBINSTL FUL 1 Preparing Door if necessary Drill holes 1 2 way thru door then complete from other side to prevent splitting Ø2 1 8 2 3 8 or 2 3 4 Ø1 Template 4 or 5 5 ...

Page 5: ...5 P N Rev B YRL EMICL PBINSTL FUL 2 Installing Strike Plates Door Frame Inside of Door Frame 1 Dia x 1 Deep 1 Dia x 1 2 Deep Frame 7 16 8 32 x 1 UNCWS x4 ...

Page 6: ...rd Right Hand Hinges Right RH Open Inward Right Hand Reverse Hinges Right RHR Open Outward The hand of a door is determined from the secure side of the door The term secure means the side from which you initially unlock and enter Determining Handing 6 P N Rev B YRL EMICL PBINSTL FUL ...

Page 7: ... B YRL EMICL PBINSTL FUL 3 Changing Handing if necessary 4 24 x 1 4 PPHMS 4 Left Hand to 4 Right Hand Shown x2 3 DO NOT TAMPER WITH OR LOOSEN E CLIP AND ITS ASSEMBLY DO NOT LOOSEN THESE 6 SCREWS OR REMOVE COVER ...

Page 8: ...Changing Handing if necessary continued 3 8 P N Rev B YRL EMICL PBINSTL FUL ...

Page 9: ... Rev B YRL EMICL PBINSTL FUL Lockset Handing Configurations 4 Left Hand For 5 5 For 4 4 Right Hand For 5 5 For 4 After handing is changed check that lever and thumbturn rotate freely Test Lever and Thumbturn ...

Page 10: ...10 P N Rev B YRL EMICL PBINSTL FUL 4 Installing Fire Cups Inside of Door Both Fire Cups and a marked UL Latchbolt must be used to qualify for listing UL ...

Page 11: ...11 P N Rev B YRL EMICL PBINSTL FUL 5 Adjusting Deadbolt Latch If adjustable deadbolt latch provided O optional default UP 2 3 8 position UP 2 3 4 position Press Pull ...

Page 12: ...Latch Latchbolt x4 7 16 8 32 x 1 UNCWS Curved edge of latchbolt faces direction door closes Choose latchbolt based on backset 2 3 8 or 2 3 4 Inside of Door Bolt must be in retracted unlocked position before installing Ensure arrow stamped on deadbolt is UP UP ...

Page 13: ...13 P N Rev B YRL EMICL PBINSTL FUL M6x55 PPHMS x2 7 Installing Exterior Deadbolt UP UP Inside of Door ...

Page 14: ...14 P N Rev B YRL EMICL PBINSTL FUL 8 Installing Lock Chassis 10 32 x 1 1 2 PPHMS Inside of Door x2 UP ...

Page 15: ...P N Rev B YRL EMICL PBINSTL FUL 9 Securing Back Plate to Door x2 Two 6 32 x 1 2 POHMS screws must be used to qualify for listing UL Drill two pilot holes Ø1 8 x 1 2 deep Inside of Door UP 6 32 x 1 2 POHMS ...

Page 16: ...16 P N Rev B YRL EMICL PBINSTL FUL Testing Deadbolt Latchbolt Operation Outside of Door ...

Page 17: ...17 P N Rev B YRL EMICL PBINSTL FUL 10 Attaching the Cable Assembly Cable must be routed as shown to avoid interference with movement of lock Test that cables are securely connected UP Inside of Door ...

Page 18: ...18 P N Rev B YRL EMICL PBINSTL FUL 11 Installing Interior Lock Turn thumbturn to adjust slot orientation UP Orientation must match Do not fasten lock to back plate until properly fitted Inside of Door ...

Page 19: ...19 P N Rev B YRL EMICL PBINSTL FUL 11 Installing Interior Lock continued 10 32 x 5 8 POHMS x1 6 32 x 1 PPHMS x2 Inside of Door DO NOT LOOSEN THIS SCREW ...

Page 20: ...20 P N Rev B YRL EMICL PBINSTL FUL Pull lever to ensure it is secure 12 SNAP Installing Interior Lever Inside of Door Inside of Door ...

Page 21: ...21 P N Rev B YRL EMICL PBINSTL FUL Testing Final Latchbolt Operation Outside of Door Inside of Door ...

Page 22: ...Testing Final Deadbolt Operation 22 P N Rev B YRL EMICL PBINSTL FUL ...

Page 23: ...23 P N Rev B YRL EMICL PBINSTL FUL If testing fails go back to beginning of Step 11 and check installation Testing Final Deadbolt Operation ...

Page 24: ... DO NOT install network module with batteries in unit Damage may occur Bolt must be in retracted unlocked position before installing batteries Tighten screw to replace cover 14 Installing Batteries Cover 24 P N Rev B YRL EMICL PBINSTL FUL ...

Page 25: ... Press to Select Press to complete Lock will cycle motor to complete handing AFTER installing batteries and cover or a factory reset AFTER create Master code PIN See 1 of Programming Instructions Congratulations you ve installed the Yale Assure Lock Electronic Interconnected Push Button Continue with the Programming Instructions to customize your product ...

Page 26: ...he backset of door relative to adjustments already made to bolt c Verify proper door preparation and re bore holes that are too small or misaligned d Verify keypad wire harness is routed properly see Step 10 e Verify bolt is installed with correct side up see Step 6 Keypad numerics are scrolling Remove interior lock and check to ensure that the wire harness is routed properly see Step 10 Door is b...

Page 27: ...r gasket C Remove two screws holding plastic guide in place D Remove plastic guide E Remove screw with washer holding cylinder in place visible after removing plastic guide F Remove cylinder housing by pulling cylinder tailpiece away from keypad 2 To Install new cylinder A Reverse previous steps for removing cylinder A B C D F E ...

Page 28: ...n Master Code must be created before any further programming PIN Max User Codes 250 with Z Wave Plus or ZigBee network module Max User Codes 25 without network module or with iM1 network module Max User Codes 12 with Bluetooth Keypad Low Battery Warning Flashes RED Lock out Mode Keypad Flashes ...

Page 29: ...erformed upon installation or after PIN resetting the lock to factory default Programming and use of lock is not possible until this step has been successfully completed Press Press Enter 4 8 digit Master Code PIN Press Press 29 P N Rev B YRL EMICL PBINSTL FUL ...

Page 30: ...codes 250 with Z Wave Plus or ZigBee network module Max user codes 25 without network module or with iM1 network module Max user codes 12 with Bluetooth 30 P N Rev B YRL EMICL PBINSTL FUL Enter Master code PIN Press Enter 4 8 digit code User PIN Press Press Press Press Press ...

Page 31: ...ng Door with Code PIN PIN Code Management With Network Module Up to 250 Users Duplicate if necessary User Name PIN Code Master User User User User User User Code Chart User User User User Type User User User User User User Unlock Enter PIN Press ...

Page 32: ...See image at right 3 Re insert 3 batteries and insert a small screwdriver into the hole holding the reset button for 3 seconds 4 While still holding the reset button insert the 4th battery and hold the reset button for an additional 3 seconds 5 Release the reset button 6 Re install the interior lock onto the door Upon reset Master Code creation is the PIN only option available and must be performe...

Page 33: ...Master Code It must be created prior PIN The Master code is used for programming and for feature settings PIN to programming the lock The Master code will also operate unlock lock the lock Network Module Setting With the optional Network Module installed this setting becomes available thru the Main Menu 7 and allows the lock to connect with a network controller One Touch Locking When the latch is ...

Page 34: ...are Troubleshooting Audio Mode N A All Code Lockout Mode Network Setting Join the network Enable Enable Disable Exit the network Disable For quiet areas select Disable 3 in Audio Mode Continue Complete Continue Complete U U Privacy Button Setting Enable Disable Handing the Lock Preforms automatic handing of the lock Master Code Setting PIN M User Codes Enter Delete Advanced Lock Settings 1 25 with...

Page 35: ... of 4 to 8 digits to register The same code cannot be used for multiple users PIN Registration management of codes is set by the PIN authority of the Master Code Contact the Master user User codes must be entered within 5 seconds or the process will have to be restarted Check mark or gear cannot be used as part of the Upon entering a code PIN and pressing the key the lock gives a series of beeps f...

Page 36: ...se the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio technician for help TV Industry Canada This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Cet appareillage numérique de la classe A répon...

Page 37: ...ollow the instructions included with it Removing a Yale Z Wave Plus Smart Module from your Assure Lock Z Wave System 1 Install the Yale Smart Module into the slot above the battery compartment IMPORTANT The batteries must be removed before removing the Yale Smart Module Remove battery cover Remove batteries Insert or remove Yale Smart Module Reinstall batteries Reinstall battery cover 2 Open the Z...

Page 38: ...e le risque d interférence aux autres utilisateurs le type d antenne et son gain doivent être choisies de façon que la puissance isotrope rayonnée équivalente PIRE ne dépasse pas ce qui est nécessaire pour une communication réussie Section 7 1 3 of RSS GEN This Device complies with Industry Canada License exempt RSS standard s Operation is subject to the following two conditions 1 this device may ...

Page 39: ...e Locks Z Wave Plus v 2 System Integr ator s Guide for Mar keting Yale Assur e Elect r onic Deadbolt s YRD216 ZW3 YRD226 ZW3 YRD256 ZW3 YRC216 ZW3 YRC226 ZW3 YRC256 ZW3 Document Revision 1 4 October 20 2020 ...

Page 40: ...2 Contents Yale Z Wave Plus Product Info 3 Supported Command Classes 3 Association Table 4 Notifications Table 4 Configurable Parameters 9 ...

Page 41: ...utton Deadbolt o 0x8002 for YRD226 ZW3 YRC226 ZW3 YRD256 ZW3 YRC256 ZW3 Touch Screen Deadbolt Supported Com m and Classes Command Class Z Wave Plus Info Command Class Manufacturer Specific Command Class Security Command Class Security 2 Command Class Device Reset Locally Command Class Power Level Command Class Version Command Class Battery Command Class Door Lock Command Class Door Lock Logging Co...

Page 42: ...fication_Report Command_Class_Door_Lock V4 o Door_Lock_Operation_Report o Door_Lock_Configuration_Report Command_Class_Device_Reset_Locally V1 o Device_Reset_Locally_Notification Command_Class_Indicator V3 o Indicator_Report Command_Class_User_Code V2 o User Code Report Command_Class_Clock V1 o Clock_Report Notifications Table Table 2 Notifications Table Alarm Reports Alarm type Alarm Level Descri...

Page 43: ...01 Manual Unlock 0x16 0x01 By key cylinder or inside thumb turn 0x06 0x02 RF Operate Lock 0x18 0x01 by RF module 0x06 0x03 RF Operate Unlock 0x19 0x01 by RF module 0x06 0X04 Auto Lock Operate Locked 0x1B 0x01 Auto re lock cycle complete locked 0x06 0x09 User deleted 0x21 0x 01 max users User was deleted Alarm level user slot number 0x06 0X0D single 0X0C all Door State 0x23 0x00 Door is open 0x06 0...

Page 44: ...ified user ID 0x06 0xFE Master Code changed 0x70 0x00 Master code was changed at keypad 0x06 0x12 0xFB Master code was changed over RF 0x06 0x0E User added 0x 01 max users User added Alarm level user slot number 0x06 0X0E Duplicate Pin code error 0x71 0x 01 max users Where Alarm level represents user slot number Alarm generated in response to add user RF cmd This alarm is not generated when attemp...

Page 45: ...arm 0xA1 0x01 keypad attempts exceed code entry limit 0x06 0X10 0x02 front escutcheon removed from main 0x06 0xFE Battery is fully charged 0x80 0x05 After a low battery alert was observed the lock was powered down and powered back up with full battery 0x08 0x0D Door Lock needs Time set 0x82 0x00 Power to the lock was restored and the locks RTC was cleared The controller should set the time to ensu...

Page 46: ...supports a 3rd low battery alarm too low to operate This alarm is sent out as a Battery Report with value 0xFF through the Battery Command Class This is the last low battery alarm level before the product stops functioning ...

Page 47: ...ck feature to enable or disable 45 3 Relock time Signed Integer 1 byte 0x0A 10 seconds 0xB4 180 seconds 0x1E 30 seconds Adjust the time your lock will auto relock 43 4 Wrong Code Entry Limit Signed Integer 1 byte 0x03 0x0A 0x05 Adjust the limit for wrong code entries allowed by your lock 61 5 Language Signed Integer 1 byte 0x01 English 0x03 French 0x01 English Set the language to English 1 Spanish...

Page 48: ...xFF Enable Set One Touch Locking feature to enable or disable 51 12 Privacy Button Unsigned Integer 1 byte 0x00 Disable 0xFF Enable 0x00 Disable Set Privacy Button feature to enable or disable 48 13 Lock Status LED Unsigned Integer 1 byte 0x00 Disable 0xFF Enable 0x00 Disable Set Lock Status LED feature to enable or disable 57 15 Reset To Factory Defaults Unsigned Integer 1 byte 0x01 0x01 N A Lock...

Reviews: