All Code Lockout Mode
:
This feature is enabled by the Master PIN code. When enabled, it restricts all
user PIN code access (
except
the Master PIN code). When the unit is in Lockout Mode, the red locked
padlock (see above) will appear on the screen when attempting to enter a PIN code.
Automatic Re-lock Time
: After successful code entry and the unit unlocks, it will automatically re-lock
after a default of thirty (30) seconds. Re-lock time is adjustable** from 10 - 240 seconds.
Inside Indicator Light
: Located on the interior escutcheon, it shows active status (Locked) of lock and
can be enabled or disabled in the
Advanced Lock Settings
(Main Menu selection #3).
Language Setting Mode:
Choosing English (1), Spanish (2) or French (3) becomes the (default) setting for
the lock's voice prompts.
Low Battery
: When battery power is low, the Low Battery Warning Indicator flashes RED. If battery power
is completely lost, use the cylinder key override.
Master PIN Code
: The Master PIN code is used for programming and for feature settings and
must
be registered prior to programming the lock.
The Master PIN code will also operate the lock.
Network Module Setting:
With the optional Network Module installed, this setting becomes available
through the Main Menu (7) and allows the lock to connect with a network controller.
One Touch Locking:
When the latch is retracted, activating the keypad will extend the latch;
(during Automatic Re-lock duration or when Automatic Re-lock is disabled). When One-Touch Re-lock is
not
in use (
disabled
), any valid PIN code will re-lock the lock.
Previous:
While in Menu Mode,
p
ressing this icon (#3 above) cancels the current operation and returns
the user to the previous step.
Shutdown Time
: The unit will shutdown (flashing RED) for a default** of sixty (60) seconds and not allow
operation after the wrong code entry limit (5 attempts) has been met.
Tamper Alert:
Audible alarm sounds if attempting to forcibly remove outside lock from door.
User PIN Code
: The User code operates the lock. Maximum number of user codes is 250 with Network
Module; without Network Module, maximum is 25 user codes. Note that when deleting User PIN code(s),
screen will display User Number (not PIN code) being deleted.
Volume Setting Mode
: The volume setting for PIN code verification is set to
Low (2) by default;
otherwise it can be set to
High (1)
or
Silent (3)
for quiet areas
.
Wrong Code Entry Limit
: After a specified number of unsuccessful attempts at entering a valid PIN code
the unit will shut down and not allow operation. Wrong code entry limit is adjustable** from one (1) to ten
(10) times. With no RF network enabled - default is 5 attempts; 10 with RF network enabled.
Low Battery Warning
1
Lockout Mode
2
Return to previous step
3
Status Indicators
**Adjustable only when using Network Module
Definitions