background image

P/N

-

-

Rev A

AYRD 156-INST FUL

19

!

Warning:

Changes or modifications to this device, not expressly approved by

ASSA

ABLOY Residential Group

could void the user's authority to operate the equipment.

FCC:

Contain FCC ID: 2ABFG- YRIZW2USTS1
Model: YRD156-ZW-619,605,0BP
This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant
to Part 15 of the

Rules. These limits are

FCC

designed to provide reasonable protection against
harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However, there
is no guarantee that interference will not occur in a
particular installation. If this equipment does cause
harmful Interference to radio or television reception,
which can be determined by turning the equipment
off and on, the user is encouraged to try to correct
the interference by one or more of the following
measures:

Ÿ

Reorient or relocate the receiving antenna.

Ÿ

Increase the separation between the equipment
and receiver.

Ÿ

Connect the equipment into an outlet on a circuit
different from that to which the receiver is

connected.

Ÿ

Consult the dealer or an experienced radio/TV
technician for help.

THIS DEVICE COMPLIES WITH PART

OF THE FCC

15

RULES OPERATION IS SUBJECT TO THE FOLLOWING

.

TWO CONDITIONS.
(1) THIS DEVICE MAY NOT CAUSE HARMFUL
INTERFERENCE AND

THIS DEVICE MUST ACCEPT

,

(2)

ANY INTERFERENCE RECEIVED INCLUDING

,

INTERFERENCE THAT MAY CAUSE UNDESIRED
OPERATION.

Industry Canada:

Contain 11626A- YRIZW2USTS1
Model: YRD156-ZW-619,605,0BP

Section 7.1.2 of

-

RSS GEN

Under Industry Canada

regulations, this radio transmitter may only operate
using an antenna of a type and maximum (or lesser)
gain approved for the transmitter by Industry Canada.
To reduce potential radio interference to other users,
the antenna type and its gain should be so chosen
that the equivalent isotropically radiated power
(e.i.r.p.) is not more than that necessary for
successful communication.
En vertu des règlements d'Industrie Canada, cet
émetteur radio ne peut fonctionner avec une antenne
d'un type et un maximum (ou moins) approuvés pour
gagner de l'émetteur par Industrie Canada. Pour
réduire le risque d'interférence aux autres
utilisateurs, le type d'antenne et son gain doivent
être choisies de façon que la puissance isotrope
rayonnée équivalente (

) ne dépasse pas ce qui

PIRE

est nécessaire pour une communication réussie.

Section 7.1.3 of

-

RSS GEN

This Device complies with

Industry Canada License-exempt

standard(s).

RSS

Operation is subject to the following two conditions:
1) this device may not cause interference, and 2) this
device must accept any interference, including
interference that may cause undesired operation of
the device.
Cet appareil est conforme avec Industrie Canada RSS
standard exemptes de licence(s). Son fonctionnement
est soumis aux deux conditions suivantes: 1) ce
dispositif ne peut causer des interférences, et 2) cet
appareil doit accepter toute interférence, y compris
les interférences qui peuvent causer un mauvais
fonctionnement du dispositif.

This radio transmitter 6982A-

0

has

YRHCPZW FM

been approved by Industry Canada to operate with
the antenna types listed below with the maximum
permissible gain indicated. Antenna types not
included in this list, having a gain greater than the
maximum gain indicated for that type, are strictly
prohibited for use with this device.

Le présent émetteur radio 6982A-

0

a

YRHCPZW FM

été approuvé par Industrie Canada pour fonctionner
avec les types d'antenne énumérés ci-dessous et
ayant un gain admissible maximal. Les types
d'antenne non inclus dans cette liste, et dont le gain
est supérieur au gain maximal indiqué, sont
strictement interdits pour l'exploitation de l'émetteur.

CAN ICES

NMB

-3B/

-3B

Summary of Contents for Real Living YRD156

Page 1: ...ouchscreen Deadbolt with Z Wave Plus Installation and Programming Instructions x4 x2 Silver x3 8 32 x 5 16 Machine screws 7 wood 8 32 machine x 20mm Combination screws M6x55mm PPHMS 2 1 4 OR x2 Black...

Page 2: ...P N Rev A AYRD 156 INST FUL 2 Preparing Door and Touchscreen Escutcheon Cup must be removed from escutcheon if bore hole is less than 2 1 8 2 1 8 Application 2 1 8 Application...

Page 3: ...A AYRD 156 INST FUL 3 x4 1 Installing Latch Strike Plate Rotate 2 3 8 position 2 3 4 position O optional Bolt must be in retracted unlocked position UP arrow must be facing upwards default 2 3 8 2 3...

Page 4: ...v A AYRD 156 INST FUL 4 2 Installing Touchscreen Escutcheon Outside of Door Ensure cable is routed under the deadbolt If bore hole is less than 2 1 8 remove cup by gently compressing two tabs while pu...

Page 5: ...P N Rev A AYRD 156 INST FUL 5 x2 3 Installing Interior Mounting Plate Choose through bolt appropriate for your door thickness...

Page 6: ...6 4 Attaching the Cable Assembly P N Rev A AYRD 156 INST FUL...

Page 7: ...P N Rev A AYRD 156 INST FUL 7 x3 5 Installing Interior Escutcheon Thumbturn should be in vertical position...

Page 8: ...P N Rev A AYRD 156 INST FUL 8 Testing Operation Deadbolt should extend and retract smoothly If not go back to step 2 Bolt must be in retracted unlocked position before installing AA batteries...

Page 9: ...UL 9 Initial Programming Press Enter new Master PIN code 4 8 digits Press to complete Lock will not operate until gear is pressed and Master PIN code is set After entering the Master PIN code press an...

Page 10: ...YRD 156 INST FUL 10 6 Installing Cover Congratulations you ve installed the Yale Real Living YRD156 Key Free Touchscreen Deadbolt with Z Wave Plus Continue with Programming Instructions to customize y...

Page 11: ...hanges or modifications to this device not expressly approved by ASSA ABLOY Residential Group could void the user s authority to operate the equipment Low Battery Warning Flashes RED All Code Lockout...

Page 12: ...12 Changing Master Code PIN 1 Press Press Enter 4 8 digit Master Code PIN Enter Master code PIN Press Press Press P N Rev A AYRD 156 INST FUL...

Page 13: ...g User Codes PIN 2 Press Enter Master code PIN Press Enter 4 8 digit code PIN Press Press Press Press Press Master code must be created first PIN Max User Codes 250 in network P N Rev A AYRD 156 INST...

Page 14: ...P N Rev A AYRD 156 INST FUL 14 3 Unlocking Door with Code PIN Press Unlock Enter PIN Press PIN Code Management Up to 250 Users in network Duplicate if necessary User Name PIN Code Code Chart...

Page 15: ...Master Code NOTE press any key to complete handing of the lock Adding Lock To Z Wave Plus Network Your network controller first needs to be in inclusion or exclusion mode for the lock to be added or...

Page 16: ...V battery in either direction to terminals below the touchscreen for backup power option Wake up the lock and enter your pin code to unlock the door Master Code It must be created prior to PIN The Mas...

Page 17: ...ng Code Entry Limit 5 Times Shutdown Time 60 Seconds The Master code must be registered prior to any other programming of the lock PIN Default settings in bold M U Master Code Setting PIN User Code Re...

Page 18: ...P N Rev A AYRD 156 INST FUL 18 Programming Troubleshooting Symptom Suggested Action...

Page 19: ...the transmitter by Industry Canada To reduce potential radio interference to other users the antenna type and its gain should be so chosen that the equivalent isotropically radiated power e i r p is...

Page 20: ...yright 2018 All rights reserved Reproduction in whole or in part without the express written permission of ASSA ABLOY Residential Group is prohibited NOTE TO INSTALLER AND CONSUMER While Yale has incl...

Page 21: ...1 Yale Locks Z Wave Plus System Integrators Guide Yale YRD156...

Page 22: ...2 Contents Yale Z Wave Plus Product Info 3 Supported Command Classes 3 Association Table 3 Notifications Table 4 Configurable Parameters 6...

Page 23: ...s Battery Command Class Door Lock Command Class Door Lock Logging Command Class Schedule Entry Lock Command Class User Code Command Class Time Parameters Command Class Time Command Class Association C...

Page 24: ...s Where Alarm level represents user slot number 0xFB Master Code Manual Lock 0x15 0x01 by key cylinder or inside thumb turn 0x02 by touch function lock and leave 0x03 By inside button RF Operate Lock...

Page 25: ...arm will be sent instead of the non access alarm Daily Repeating Schedule Set Erased 0x60 0x 01 max users Schedule s has been set erased for specified user ID Daily Repeating Schedule Enabled Disabled...

Page 26: ...default is 30 seconds Wrong Code Entry Limit 4 1 byte 3 to 10 default is 5 times Shut down time after wrong code entries 7 1 byte 10 to 180 seconds default is 60 seconds operating mode 8 1 byte 00 nor...

Reviews: