10
Command Class Version, Version 3*
* This command class requires security.
The Yale Real Living locks are a multi-processor system with 1 additional firmware
target. All processors can be updated through the Firmware Update Meta Data
command class. The firmware targets are numbered as follows:
•
Firmware Target 0 = Z-Wave
™
Chip
•
Firmware Target 1 = Lock Processor
To identify the firmware version for each target, the hex data in the firmware
version report must be converted to decimal prior to combining major and minor
version into the full version.
After a controller sends a Version Get command the log will display the Version
Report similar to the below:
The above Version Report will be defined as this in the Z-Wave
™
sniffer tool,
Zniffer:
For Firmware Target 0, the Firmware 0 Version (0x02) and Sub version (0x22)
translate to module firmware decimal value of “2.34”.
For Firmware Target 1 (the data under vg1), Firmware Version (0x2C) and Sub
version (0x00) translate to lock firmware decimal value of “4.3.00”.