The Yale Real Living™ Stand-alone Touchscreen Deadbolt Lock combines a robust lockset with a 
contemporary electronic aesthetic.
Users benefit from an interactive touchscreen that makes day-to-day access effortless, as well as 
offering voice-guided programming for simple updates to user information in the event of staffing 
changes or security breaches. Yale Real Living™ is engineered for quick and easy installation and 
fits in place of a standard deadbolt lock door prep (ANSI/BHMA A156.115).
If this is an RF-enabled network lock, it needs to be located within 50 - 100 feet of another network 
controller. That distance is influenced by objects between the lock and the controller and may be 
expanded depending on proximity to other RF network devices. Also, if the lock is connected to a 
network controller, it is recommended that it is programmed through the centralized user interface 
(PC or hand-held device) to ensure communication between the lock and the controller unit. 

Industry Canada:

Canadian ID: 6982A-YRHCPZW0 (Z-Wave); 6982A-YRHCPZB0 (Zigbee)

This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment 
Regulations. Operation is subject to the following two conditions: (1) this device may not cause harmful 
interference, and (2) this device must accept any interference received, including interference that may 
cause undesired operation. 

Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne 
causant des règlements d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce 
dispositif peut ne pas causer l’interférence nocive, et (2) ce dispositif doit accepter n’importe quelle 
interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée.

For the U4A-YRHCPZB0 and 6982A-YRHCPZB0, the following statement applies:

“This equipment complies with FCC/IC radiation exposure limits set forth for an uncontrolled 
environment. This equipment should be installed and operated with minimum distance 20cm between 
the radiator and your body. This transmitter must not be co-located or operating in conjunction with any 
other antenna or transmitter.”

Section 7.1.2 of RSS-GEN 

Under Industry Canada regulations, this radio transmitter may only operate 

using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry 
Canada. To reduce potential radio interference to other users, the antenna type and its gain should be 
so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for 
successful communication.
En vertu des règlements d'Industrie Canada, cet émetteur radio ne peut fonctionner avec une antenne 
d'un type et un maximum (ou moins) approuvés pour gagner de l'émetteur par Industrie Canada. Pour 
réduire le risque d'interférence aux autres utilisateurs, le type d'antenne et son gain doivent être choisies 
de façon que la puissance isotrope rayonnée équivalente (PIRE) ne dépasse pas ce qui est nécessaire 
pour une communication réussie.

Section 7.1.3 of RSS-GEN 

This Device complies with Industry Canada License-exempt RSS standard(s). 

Operation is subject to the following two conditions: 1) this device may not cause interference, and 2) 
this device must accept any interference, including interference that may cause undesired operation of 
the device.
Cet appareil est conforme avec Industrie Canada RSS standard exemptes de licence(s). Son 
fonctionnement est soumis aux deux conditions suivantes: 1) ce dispositif ne peut causer des 
interférences, et 2) cet appareil doit accepter toute interférence, y compris les interférences qui peuvent 
causer un mauvais fonctionnement du dispositif.

Summary of Contents for Real Living

Page 1: ...able on our website in printed Spanish and French Go to www yalerealliving com Click Product Information Documentation and then Installation Instructions Este documento está disponible en español en nuestra página de internet Vaya a www yalerealliving com Presione Información del Producto y Documentación y luego Instrucciones de Instalación Ce document est disponible sur notre site Web dans le fra...

Page 2: ...ccur in a particular installation If this equipment does cause harmful Interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment ...

Page 3: ... y compris l interférence qui peut causer l opération peu désirée For the U4A YRHCPZB0 and 6982A YRHCPZB0 the following statement applies This equipment complies with FCC IC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance 20cm between the radiator and your body This transmitter must not be co located or opera...

Page 4: ... AA Alkaline Batteries 2 Through bolts Keys Bolt Quick Start Guide Installation Instructions Door Marker Outside Escutcheon Bolt Strike Plate Screw Pack see below Keys Included in the box Inside Escutcheon Inside Mounting Plate Battery Cover 4 AA Alkaline Batteries Strike Plate 4 Bolt Strike Plate Mounting Screws 3 Inside Escutcheon Mounting screws Network Module Optional Inside Mounting Plate wit...

Page 5: ...ottom of battery cover 3 Remove the inside mounting plate with gasket from the back door side of the inside escutcheon Battery Cover Inside Escutcheon C The outside escutcheon with gasket remains assembled B Bolt Note Bolt ships with backset in 2 3 8 posi tion If required press small black button on underside of bolt and pull to extend to 2 3 4 backset position Fig 3B Inside Escutcheon Mounting Pl...

Page 6: ... escutcheon As you position the outside escutcheon route the wire harness through 2 1 8 diameter hole Figure 3A NOTE Wire harness goes under bolt Fig 3B Figure 3B 5 Secure both assemblies using 2 M6 x 59 5mm pan head machine screws Fig 4B making sure that outside escutcheon is vertically aligned Hand tighten until snug Do not over tighten Inside of Door Figure 4B Figure 4A Tongue Inside of Door 4 ...

Page 7: ...embling to ensure that the cable lies against the back recessed area of the inside escutcheon Use the cable hook Note label on circuit board as shown in Figures 6A 6B to prevent binding when installing the escutcheon over the mounting plate NOTE Connector should be pressed in firmly using thumbs until completely seated Proper position is indicated by arrows on PCB as in Figures 6A 6B and 6C Route ...

Page 8: ...ne batteries The lock will flash beep several times and respond with the vocal prompt Welcome to Yale Real Living When activating the lock for the first time the lock will adjust for proper handing Note Refer to programming instructions in following section prior to completion of next step 10 10 Install battery cover and tighten Phillips head screw NOTE The bolt must be in a retracted unlocked pos...

Page 9: ...cons Used in This Guide Touch the screen with back of hand or fingers to begin and end actions Repeat operation using settings indicated Press the indicated number Enter Master PIN code 4 8 digits in length Press the Star key on the touchscreen to Enter or Accept entry Enter User PIN code Can be 4 8 digits in length Press the Pound key on the touchscreen to enter Menu mode User Number 1 25 RF Netw...

Page 10: ...available through the Main Menu 7 and allows the lock to connect with a network controller One Touch Locking When the latch is retracted activating the keypad will extend the latch during Automatic Re lock duration or when Automatic Re lock is disabled When One Touch Re lock is not in use disabled any valid PIN code will re lock the lock Previous While in Menu Mode pressing this icon 3 above cance...

Page 11: ... factory default Programming and subsequent use of the lock is not possible until this step has been successfully completed Touch screen with the back of your hand or fingers to activate Press the key followed by the key OPERATION Protect your privacy always shield your PIN code entry 1 Touch the screen with the back of your hand or fingers to activate 2 Press the key Lock Response Register Master...

Page 12: ...ries are properly installed release the reset button All features including adjustable settings see below should now be returned to factory default Upon reset Master Code Registration is the only option available and must be performed prior to any other programming of the lock See Operation in this manual for programming instructions Reset Lock to Factory Default Adjustable only when using Network...

Page 13: ...ing User codes the code must be entered within 20 seconds or time expires Lock Response Time expired no codes are registered and the process must be re started 3 Press the key to confirm the selection Enter PIN code 2 1 Touch lock with back of hand or fingers to activate PIN code structure Maximum number of user codes is 250 with Network Module without Network Module maximum is 25 user codes Open ...

Page 14: ...ded that it is programmed through the centralized user interface PC or hand held device to ensure communi cation between the lock and the controller unit The Master PIN code must be registered prior to any other programming of the lock Enable Disable Privacy Button Setting Handing the Lock Enable Disable 1 Enter the 4 8 digit Master PIN code followed by the key 2 Enter digit corresponding to the f...

Page 15: ...olt and or strike which may be preventing bolt from properly entering the strike With the door open extend and retract the bolt if it is smooth check the strike alignment Bolt does not extend or retract smoothly a Bolt and strike are misaligned see above b Check the backset of door relative to adjustments already made to bolt c Verify proper door preparation and re bore holes that are too small or...

Page 16: ...er Registration management of PIN codes is set by the authority of Master Code The Master PIN code must be registered prior to adding any users PIN codes must consist of 4 to 8 digits to register The same PIN code cannot be used for multiple users Contact the Master user User codes must be entered within 5 seconds while the touchscreen is active or the process will have to be restarted The star or...

Page 17: ...eries must be removed prior to removing and or inserting the network module Remove battery cover Remove batteries Remove and or insert network module Reinstall batteries Installing the Network Module Use feature programming step 7 page 14 for enrollment of the Network Module ...

Page 18: ...s spring E Remove cylinder by pulling outward towards outside of door Before installing cylinder please be sure tailpiece is correct length see below How to Replace or Install Cylinder 1 3 8 to 2 thick doors L 3 1 2 88 8mm 2 to 2 1 4 thick doors L 3 3 4 95 3mm Requires addition of Thin Door Kit A B D C L Cylinder tailpiece information T 098 2 5mm W 2 5 2mm w T Tailpiece E 2 Install new cylinder A ...

Page 19: ...work Module Up to 25 Users Location Door Number User User Name User PIN Code User Type User Name User PIN Code Master User 13 User 01 User 14 User 02 User 15 User 03 User 16 User 04 User 17 User 05 User 18 User 06 User 19 User 07 User 20 User 08 User 21 User 09 User 22 User 10 User 23 User 11 User 24 User 12 User 25 ...

Page 20: ...er ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User _...

Page 21: ...rademark of Yale Security Inc an ASSA ABLOY Group company All rights reserved Yale Real Living is a trademark of Copyright 2013 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without express written permission of Yale Security Inc an ASSA ABLOY Group company is prohibited YALE with its unique global reach and range of products is the world s favo...